![SCS PTC-IIIusb User Manual Download Page 184](http://html1.mh-extra.com/html/scs/ptc-iiiusb/ptc-iiiusb_user-manual_1219876184.webp)
13 TRX
174
Data from the receiver is not reformatted by the PTC-IIIusb, but simply fed through
directly to the terminal. For the
Frequency
command without argument not the offset
corrected frequency in kHz will be displayed, but the original string from the transceiver.
The fourth argument defines if the tranceiver is controlled with TTL or V24 levels. Refer
to the transceivers manual to determine if it requires TTL or V24 levels.
If your transceiver has a 9-pole SUD-D connector for remote-control then it´s most
propable that it uses V24 levels.
CODAN
If the first parameter is “Codan”, the
TYpe
command only allows up to 2 parameters.
PTC-II modems with V24 support always work in mode “V24” if
TYpe
is set to
“Codan”. (Codan transceivers are V24 compatible.)
The function of the transfer command (trx t ...) for Codan transceivers is identical to the
function for Kenwood transceivers, i.e. ASCII strings are simply transferred
transparently.
ATTENTION:
In order that Codan NGT transceivers accept commands at a remote port (“RS232 15-
way” or “RS232 9-way”), the CICS command must be activated (config menu, only after
admin login).
Another, very important restriction must be considered: Only frequencies that are
predefined in a “channel” (within the transceiver) can be chosen through the remote port.
If an exact match cannot be found, the channel with the next higher frequency is selected.
Commands for different transceivers:
trx:
TY
C 38400 <Return>
trx:
TY
I 1200 4 <Return>
trx:
TY
I 1200 $1C <Return>
trx:
TY
K 4800 A <Return>
trx:
TY
K 4800 A V <Return>
trx:
TY
N 4800 2 <Return>
trx:
TY
Y 9600 B <Return>
trx:
TY
S 9600 <Return>
If less that four arguments are given, the PTC-IIIusb only changes the explicitly given
parameters. The command
TY
I 9600 <Return> for example sets only the type to ICOM
and the baudrate to 9600 Bd. The equipment address remains unchanged.
For the moment, with the TRX type NMEA ICOM only setting the frequency is
supported and also scanning. Frequency readback as well as
Transfer
is not possible.
13.18
Wait
Default setting: 10
Parameter: X 1... 240, time in seconds.