10
F
3.6
SW2/SW6
SETTING
Default
ON
OFF
OFF
OFF
Device
SWITCH
SWITCH
4 and 5
on ON
SWITCH
4 and 5
on ON
SWITCH
4 ON
and 5 OFF
SWITCH
4 OFF
and 5 ON
Button
BUTTON A
BUTTON B
BUTTON C
BUTTON D
BUTTON A
BUTTON B
BUTTON C
BUTTON D
BUTTON A
BUTTON B
BUTTON C
BUTTON D
BUTTON A
BUTTON B
BUTTON C
BUTTON D
Description
TOTAL OPENING
PEDESTRIAN ACCESS
RELEASE RELAY EXT+ AND EXT- DEVICE 1 ET 2
RELEASE RELAY EXT+ AND EXT- DEVICE 1 ET 2
TOTAL OPENING
RELEASE RELAY EXT+ AND EXT- DEVICE 1 ET 2
PEDESTRIAN ACCESS
PEDESTRIAN ACCESS
TOTAL OPENING
RELEASE RELAY EXT+ AND EXT- DEVICE 1 ET 2
NOT USED
PEDESTRIAN ACCESS
TOTAL OPENING
RELEASE RELAY EXT+ AND EXT- DEVICE 1 ET 2
PEDESTRIAN ACCESS
NOT USED
SW2
Default
1-ON
2-ON
3-ON
4-ON
5-ON
6-ON
Photocell 1
Photocell2
Stop
Remote control
Remote control
Remote control
Remark
If no photocells are
connected, 1 and 2
must stay on ON
position
Description
Switch onON if photocells N°1 are not connected
Switch on OFF if photocells N°1 are connected
Switch on ON if photocells N°2 are not connected
Switch on OFF if photocells N°2 are connected
Switch on ON if nothing is connected on device 11 and 12
Switch on OFF if stop command is connected on device 11 and12
To SW2
To SW2
To SW2
SW6
A
B
C
D
OFF
OFF
ON
ON
1
Ph1
2
Ph2
3
Stop
4
D
5
C
6
SW6
SW2