SCS 770758 Installation, Operation And Maintenance Manual Download Page 4

TB-9094

 Page 4 of 7

© 2019 DESCO INDUSTRIES INC

Employee Owned

SCS 

- 926 JR Industrial Drive, Sanford, NC 27332

East: (919) 718-0000 | West: (909) 627-9634 • Website: 

StaticControl.com

INSTALLING THE DUAL COMBINATION TESTER 

AND STAND

1.  Assemble the pedestal and base plate using the 5 

socket head screws. 

2.  Route the ground cord, foot plate cord, and power 

adapter through the pedestal. Feed the cords from 

the bottom and have them exit through the top. 

3.  Align the backplate’s two holes located above and 

below the tester to the two holes on the pedestal’s 

mounting bracket. Secure the backplate using the 

two Phillips head screws and nuts. 

4.  Plug the ground cord into the ground jack located 

on the bottom of the tester, and connect the ring 

terminal to equipment ground. This connection will 

remove any static charge from the user before the 

test. 

NOTE: Failure to correctly ground the Dual 

Combination Tester may result in damage not 

covered under warranty. 

5.  Plug the foot plate cord into the tester and the dual 

foot plate. 

6.  Lay the dual foot plate onto the base plate. 

Figure 5. Assembling the pedestal and base plate using 

the 5 socket head screws

Figure 6. Securing the Dual Combination Tester to the 

pedestal

Figure 7. Installing the dual foot plate onto the baseplate

7.  Power the Dual Combination Tester with the power 

adapter.

Summary of Contents for 770758

Page 1: ...Combination Tester 770751 Limit Comparator 770752 Power Adapter 100 240 VAC Input 12 VDC 0 5 A Output All Plugs Per ANSI ESD S20 20 section 7 3 A Compliance Verification Plan shall be established to e...

Page 2: ...rd here to test your wrist strap F Dual Wire Wrist Strap Jack Insert your dual wire wrist cord here to test your wrist strap G Wrist Strap Status LEDs Displays the wrist strap test results H Relay Ter...

Page 3: ...ON 10 Megohms 1 x 107 ON OFF 35 Megohms 3 5 x 107 default setting DIP switch 5 must be ON default setting for the wrist strap test to be active The wrist strap test will be disabled if DIP switch 5 i...

Page 4: ...Secure the backplate using the two Phillips head screws and nuts 4 Plug the ground cord into the ground jack located on the bottom of the tester and connect the ring terminal to equipment ground This...

Page 5: ...onding jack located on the face of the Dual Combination Tester Place one foot on each foot plate 3 To begin the test use your finger to bridge the test switch s inner and outer contacts The blue stand...

Page 6: ...to ensure that they are being worn correctly and or need to be replaced NOTE Failures may be caused by dry skin or minimal sweat layer For wrist straps try using an approved dissipative hand lotion s...

Page 7: ...bs 2 5 kg Maintenance To maintain optimum performance cleaning should be performed on a regular basis Use a minimum of 80 Isopropyl alcohol to clean the foot plate and test switch Other cleaners are s...

Reviews: