SCS 770758 Installation, Operation And Maintenance Manual Download Page 1

TB-9094

 Page 1 of 7

© 2019 DESCO INDUSTRIES INC

Employee Owned

SCS 

- 926 JR Industrial Drive, Sanford, NC 27332

East: (919) 718-0000 | West: (909) 627-9634 • Website: 

StaticControl.com

Dual Combination Tester

Installation, Operation and Maintenance

Description

The SCS Dual Combination Tester verifies the 

functionality of personnel grounding devices (wrist 

straps

1

, foot grounders, ESD shoes, smocks

2

). Three 

independent tests are performed simultaneously on 

the wrist strap and each foot. Green lights indicate a 

pass condition. Red and yellow lights plus an audible 

alarm indicate when the wrist strap and/or footwear (left 

or right) have failed. DIP switches may be accessed 

for test limit preferences. Access control to an ESD 

Protected Area can be further enforced by using the 

relay terminal on the Dual Combination Tester and 

connecting it to an electronic door lock or turnstile 

to grant access only to those who have passed their 

personal grounding device tests. The Dual Combination 

Tester is calibrated to NIST standards and includes a 

certificate.
SCS Dual Combination Tester Technology

•  The solid-state touch test switch maintains test 

accuracy and extends the lifetime of the tester

•  The 30 volt test signal increases test reliability
The factory test limits are set to:

Wrist Straps:  750 kilohms and 10 megohms

Footwear: 

750 kilohms and 35 megohms

(See page 3 for alternate test limit settings)

March 2019

The Dual Combination Tester and its accessories are 

available as the following item numbers:

Item

Description

770758

Dual Combination Tester

770759

Stand, for Dual Combination Tester

770751

Limit Comparator

770752

Power Adapter, 100-240 VAC Input, 12 VDC 

0.5 A Output, All Plugs

Per ANSI/ESD S20.20 section 7.3 “A Compliance 

Verification Plan shall be established to ensure the 

Organization’s fulfillment of the technical requirements 

of the ESD Control Program Plan. Process monitoring 

(measurements) shall be conducted in accordance 

with a Compliance Verification Plan that identifies the 

technical requirements to be verified, the measurement 

limits and the frequency at which those verifications 

shall occur. The Compliance Verification Plan shall 

document the test methods and equipment used for 

process monitoring and measurements. … The test 

equipment selected shall be capable of making the 

measurements defined in the Compliance Verification 

Plan.” 
Per ANSI/ESD S1.1 Annex A.3 Frequency of System 

Testing “The wrist strap system should be tested daily to 

ensure proper electrical resistance.”
“Compliance verification should be performed prior to 

each use (daily, shift change, etc.). The accumulation 

of insulative materials may increase the foot grounder 

system resistance. If foot grounders are worn outside 

the ESD protected area testing for functionality 

before reentry to the ESD protected area should be 

considered.” (ESD SP9.2 APPENDIX B - Foot Grounder 

Usage Guidance)

Made in the

United States of America

Figure 1. SCS 770758 Dual Combination Tester and 

Dual Foot Plate

1.  The Dual Combination Tester can verify single-wire and dual-wire 

wrist straps.

2.  The Dual Combination Tester will also test a Groundable Static 

Control Garment System. The Groundable Static Control Garment 

System must have an RTG of < 3.5 x 10

 ohms to meet the 

required limit of ANSI/ESD S20.20 tested per ANSI/ESD STM2.1 
and ESD TR53.

 USER GUIDE TB-9094

Summary of Contents for 770758

Page 1: ...Combination Tester 770751 Limit Comparator 770752 Power Adapter 100 240 VAC Input 12 VDC 0 5 A Output All Plugs Per ANSI ESD S20 20 section 7 3 A Compliance Verification Plan shall be established to e...

Page 2: ...rd here to test your wrist strap F Dual Wire Wrist Strap Jack Insert your dual wire wrist cord here to test your wrist strap G Wrist Strap Status LEDs Displays the wrist strap test results H Relay Ter...

Page 3: ...ON 10 Megohms 1 x 107 ON OFF 35 Megohms 3 5 x 107 default setting DIP switch 5 must be ON default setting for the wrist strap test to be active The wrist strap test will be disabled if DIP switch 5 i...

Page 4: ...Secure the backplate using the two Phillips head screws and nuts 4 Plug the ground cord into the ground jack located on the bottom of the tester and connect the ring terminal to equipment ground This...

Page 5: ...onding jack located on the face of the Dual Combination Tester Place one foot on each foot plate 3 To begin the test use your finger to bridge the test switch s inner and outer contacts The blue stand...

Page 6: ...to ensure that they are being worn correctly and or need to be replaced NOTE Failures may be caused by dry skin or minimal sweat layer For wrist straps try using an approved dissipative hand lotion s...

Page 7: ...bs 2 5 kg Maintenance To maintain optimum performance cleaning should be performed on a regular basis Use a minimum of 80 Isopropyl alcohol to clean the foot plate and test switch Other cleaners are s...

Reviews: