8. Connect the power adapter to the power jack
located on the right-side of the monitor. Route the
wire from the power adapter to a nearby AC outlet
and plug it into the outlet. Make sure the voltage
and frequency match those listed on the power
supply. The monitor is now powered.
Antenna
Figure 6. Stand-a/one setup for the EM Aware Monitor
Relay Terminal
The EM Aware Monitor features one optical relay
terminal that can be
i
ntegrated with electronic tools,
lights, buzzers, etc. The relay opens when the monitor
enters an alarm condition, and it remains closed
otherwise. Alarm conditions include ESD events and
exceeded static voltage and ionizer balance thresholds.
Figure
7.
Relay terminal pin-out
Parameter
Rating
Peak Blocking Voltage
400 V
P
Load Current
140 mA
rms
/ mA
oc
On-Resistance (max)
22 ohms
TB-9097