![background image](http://html1.mh-extra.com/html/scs-sentinel/mco0058/mco0058_installation-and-user-manual_1219945032.webp)
32
EN
To program a remote control : Press «RF-Learn» button for 2 seconds, and the LED display shows «CS». Then
push any button of the transmitter; the LED flashes twice and then be off. And the remote memory has completed
(picture 1,2 et 3)
You can now use your remote control as follow :
To cancel the remote controls memory :
Press and maintain the «RF-Learn» button until the LED display indicates
(approx. 10 s.).
pedestrian opening
full opening
trigger relay output
EXT+ EXT-
:
The remote control memory storing operation must be over before starting the final system learning
process.
(1) To complete the system learning process, disengage your gate and remove it in the middle. Then re-engage
it again.
Step 1 : Press the button « SET », then « SET » + « DOWN » during 3 seconds, the LED display shows « LE » (Pictures
1,2 and 3, see following page)
Step 2 : Press the button on the top left of your remote control during 1 to 3 seconds, the LED display shows then
« LP » (Pictures 4 and 5)
Step 3 : The gate goes to auto-learning. It means it closes a first time then opens and closes again. Please wait
for the learning process to be completed.
LED display
ON
2 Sec
LED display
blink twice
LED display OFF
1
3
13
14
ON
OFF
LED2
LED1
2
D- SETTING / USING
D1- Remote controls
D2- System learning process, reset process and LED display
LED
viewer
LED viewer
flashes twice
LED screen turns
off