Automatic (example for blind 1)
Automatic object function
After receiving “1” on group object 20, automatic function is activated and object groups 17, 18
and 19 are deactivated.
Status Feedback
Object group 20 is set by actuator status feedback.
Automatic switching
Object group 20 is set by external group address.
Status Feedback & Automatic switching
Object group 20 is set by actuator status feedback or by external group address.
Time until automatic activation (10-minute step) deactivation by automatic object
After receiving “0” on group object 20, timer starts immediately for the set point time.
Deactivation by manual operation
Yes
No
Time until automatic activation (10-minute step) deactivation by manual operation
The timer starts as soon as a manual command (object groups 10..15) is received; when the timer
expires the system resumes the Automatic mode.
Menu Blind1
In order to allow the automatic operation of blind 1, set the “Automatic function” parameter to “Yes”