background image

 

 

 

 

 

 

Connect 240v/24v Motor Controller Change of Contact State 

 

 

 

Programming Procedure To Change Factory Contact State From 2 x Momentary 

Contact To A Single Latched Contact. 

 

 

1.  Infra Red receiver must be connected to Connect Motor Controller that you wish to change the contact state input. 

 

2.  Disconnect mains power for 20 seconds, then turn power back on. 

 

3.  A red program LED will illuminate and the Motor Controller is now in programming mode. Please note it is not 

necessary to see this programming light to proceed to point 4, as it is usually contained with a Screen Technics 

product and cannot be easily accessed. 

 

4.  Please refer to the diagram of the remote control and identify the “Stop 1”and “Stop 2” buttons before proceeding. 

Having identified these buttons press them in the following sequence: 

             

 

STOP 1 / STOP 1 / STOP 2 / STOP 2 / STOP 1 / STOP 2 

 

5.  Projection Screen or AV Lifter will acknowledge the reset with a small movement up and down, If the Projection 

screen or AV Lifter does not move you will need to start the process 

again 

 

6.  The contact close state has now been changed from 2 x Momentary 

Contact to Single Latched Contact State. 

  

7.  This operation does not change the Infra red remote transmitter 

operation. 

 

8.  To reset the ElectiCinema projection screen or AV lifter to factory 

standard please refer to the factory reset instructions – this will return 

the ElectiCinema projection screen or AV lifter to factory standard 

configuration. 

 

 

 

                               

 

 

 