background image

 

 

 6500400 – CS2 iSense 240v Current Sensing Module

  

 

The iSense device will detect a 240v current power up from a device (such as projector / plasma / LCD / amplifier 

etc) and output a single latched contact that will switch a CONNECT Motor Controller that comes with many 

Screen Technics products. 

 

Important Information – In order for the CS1 iSense to control a Screen Technics CONNECT Motor Controller, the 

green phoenix terminal on the module that is used for dry contact control has to be changed for the factory 

setting default – Momentary Contact – to a  Latched Contact setting. 

 

Please see the instructions attached to achieve the program state change. 

 

 

Instructions 

 

1.  Connect iSense to mains power via three pin 

plug 240 V Input. 

 

2.  Plug in the device – projector etc -  into the 

Connect iSense module, via the 3 pin GPO 
input . 

 

3.  Power up the device – projector etc - 

connected to the 240v output socket. 

 

4.  Adjust the sensitivity via the adjustment 

potentiometer located on the side of the case 
near the LED threshold indicator until the 
LED illuminates (this indicates that the 
iSense current sensing is above the 
minimum threshold).  

 

 

Move the potentiometer in a ANTI CLOCKWISE direction for more sensitivity. 

 

Move the potentiometer in a CLOCKWISE direction for less sensitivity. 

 

When the LED illuminates the iSense is above the minimum current threshold and the relay contact in now in the 
open position. 

 

5.  Turn the projector connected to the 240 V output socket off, the LED should go out and the relay contact is now in 

the open position (If the red LED is still illuminated the iSense sensitivity adjustment will be need to be adjusted in 
a clockwise direction until the red LED goes off. If red LED flashes on and off, turn the threshold adjustment 
further clockwise till the iSense stabilises, and the red LED stays off. 

 

6.  Now turn on the projector connected to the 240v output socket, and the LED will illuminate and when connected 

to a properly programmed CONNECT Motor Controller it will send the command to motor the projection screen or 
AV lifter down. 

 

7.  The iSense module now requires connection from the iSense relay out screw terminals to the Contact input on the 

CONNECT Motor Controller within the Screen Technics product to be controlled, please refer to product 
instructions to assist in this process. 

 

 

Should you have any questions regards the Connect iSense please contact the Technical Sales 

Office on + 61 2 4869 2100

    

 

 

Reviews: