3. Selection of breathing protector equipped with filter

 

Type of protective device 

Multiples of threshold concentration **) 

Remarks, limitations 

APF (Assigned protection factor) 

***) 

BS 4275 (GB)

 

BGR 190 - ZH1/701 (DE)

 

Half mask with particle filter P3 

20 

30 

Particles 

Half mask with gas filter *) 

10 

30 

Filter types A, B, E, K, AX, SX, Hg-P3 and NO-
P3 have different applications. For more 
information, see Instructions for Use of Scott 
Health & Safety filters. 

Device with combined filter 

The specified multiples of threshold value for the gas or particle filters 
are given separately, but in all cases the lowest value applies 

*) 

Provided that the maximum permissible detrimental gas concentration for the gas filter is not 
exceeded. 

 

For non-powered filtering devices with gas filter, concentration must not exceed 0.1 vol.% in gas filter 
class 1 and 0.5 vol.% in gas filter class 2 and 1.0 vol.% in gas filter class 3. 

**)  If national guidelines exist: in all cases the lowest value applies. 
***)  AS/NZS 1715 recommends a minimum protection factor of up to 10 for a Half mask respirator fitted 

with a P2 or P3 filter. 

 
Note! 

In Australia only, the following limitations apply:

 

 

Provides P3 protection only with a full face respirator (AS/ NZS 1716:2003 refers). 

 

Provides P2 protection with a half face respirator negative pressure respirator

 

 

4. Preparations for use

 

 

Check before use 

 

facepiece, head harness and valves are intact 

 

cover is securely in position 

 

filter is correct for the intended use. Filter type and class are evident from the marking. 

 

storage period of the filter has not been exceeded 

 

filter condition and intactness. Shake the filter to ensure that there are no loose 
components/contents. The filter shall be replaced if it has been exposed to strong press or 
impact. It may be damaged. 

 

 
 

Fitting of the filter 

 

Always use two filters of the same type and class. Always replace both filters at the 
same time. 

 

Align the bayonets on the mask with the slots on the filter and locate the filter. 

 

Turn the filter clockwise ¼ turn 

 The filter is tight only when the aligning marks (

are opposite each other and the openings of the splash guards face backwards. 

 

Fitting of the Profile

2

 Litehood

 

 

Remove the cover. Align the openings of the hood with the mask, then close the 
cover. 

 

Fit the filters, and don the hood+mask. 

 

Donning 

Fasten the neck buckle. 
Locate the chin pocket of the mask properly on the chin and pull the head 
cradle over the head. 
Adjust the straps as required. 

 

Leak check

 (two alternative methods): 

Reviews: