Using the Compressor HMI
25
SCOTT SAFETY
087-0067 REV A
Using the Compressor
HMI
The HMI has a compressor screen that displays a color-coded quick view of the
system and provides access various functions. See
Figure 10
HMI Compressor Screen
•
Auto - The compressor may be operated in one of two modes. The modes are
Automatic or Manual. In the Auto mode, the compressor starts and runs until the
pressure switch is tripped at 7000PSI and the automatically restarts when the
pressure drops to 6200PSI. The cycle is repeated.
•
Manual - In the Manual mode, the compressor starts and runs until the pressure
switch is tripped at 700PSI.
•
Stages - Displays the current pressure of the compressor. Specifically the stage 1 to
stage 5.
•
Temperature - Displays the current readings of the crankcase and air.
•
Operation - Displays the current reading of the oil pressure.
•
Maintenance - Displays the purification hours remaining.
•
Sensors - Displays the current reading of the dewpoint and CO.
•
Run - Starts the compressor.
•
Stop - Is used to manually shut down the compressor in an orderly manner. When
activated, the cool down cycle of the compressor, if needed and then power down
the remainder of the system.
Summary of Contents for HushAir Connect 7500
Page 1: ...User Guide 087 0067 Rev A HushAir Connect 7500 COMPRESSOR SYSTEM ...
Page 2: ......
Page 3: ...HushAir Connect 7500 User Guide COMPRESSOR SYSTEM 087 0067 Rev A ...
Page 8: ...IV CONTENTS 087 0067 REV A SCOTT SAFETY ...
Page 12: ...X LIST OF TABLES 087 0067 REV A SCOTT SAFETY ...
Page 42: ...20 CHAPTER 2 INSTALLATION 087 0067 REV A SCOTT SAFETY ...
Page 73: ...Configuring the System 51 SCOTT SAFETY 087 0067 REV A Figure 27 Override Status Screen ...
Page 106: ...84 CHAPTER 5 MAINTENANCE 087 0067 REV A SCOTT SAFETY Figure 48 Oil Drain Location 3 1 2 ...
Page 112: ...90 APPENDIX A SPECIFICATIONS 087 0067 REV A SCOTT SAFETY ...
Page 119: ......