Auto Function:
Press both left limit switches
and
at the same time and the device will begin pre-set operation.
Auto Function Operates from 90°L - 270°R.
Left and Right Limit
Adjust the AquaSweep to the desired rotation.
Use
and
buttons to set the left limit
and
and
to set the right limit
of the AquaSweep pattern. The display shows
“Lxxx” and “Rxxx” where “xxx” is limit angle in
degrees corresponding to the chart shown at right.
Speed
The
and
buttons will adjust the speed of the left/right movement. “SP xx” will display
where xx is the speed in degrees per minute. 1 degree per minute will take about six hours to complete a sweep
(one end to the other and back) if the left/right limits are 180 degrees apart. At 90 degrees per minute this will
take a little less than four minutes. The sweep speed can be set to zero, turning off the oscillator.
Timer
The
and
buttons set how long the device runs then how long it is idle in hours. For instance, it can run
for six hours then sleep for six hours. Pressing both together will toggle between “PAUSE” mode (system off
indefinitely) and “RUN” mode (normal operation). Press the
and
buttons together to pause the system.
Display will show “PAUSE”. Press any button to exit pause mode. Setting the off time to zero will keep the
system from turning off.
ON
TIME
RATE
RATE OFF
TIME
10°
90°
20°
30°
40°
50°
60°
180° 190°
200°
210°
220°
230°
240°
250°
260°
270°
350°