The machine is designed for use indoors in a
controlled environment. It must be kept dry, not
overheated or subjected to excessive cold. The water
and power supply must be maintained or the machine
will stop making ice.
There are limits to how hot or cold the room it’s in can
be.
• Minimum air temperature: 50
o
F or 10
o
C
• Maximum air temperature: 100
o
F or 38
o
C
There are limits to the voltage supply to the unit,
voltages vary by model:
Voltage
• Minimum 104
• Maximum 126
Water
Temperature
• Minimum water temperature: 40
o
F or 4.5
o
C
• Maximum water temperature: 100
o
F or 38
o
C.
Quality
• Water supply must be potable by the localities
definition.
Water Pressure
• Maximum pressure. static: 80 psi or 5.5 bar
• Minimum pressure, dynamic: 15 psi or 1 bar
Water Conductivity
• The water supply must have a conductivity of at
least 10 microSiemens/cm.
A drain will be needed for melted ice and rinse water
Warranty:
The warranty statement for this product is provided
separately from this manual. Refer to it for applicable
coverage. In general warranty covers defects
in material or workmanship. It does not cover
maintenance, corrections to installations, or situations
when the machine is operated in circumstances that
exceed the limitations printed above.
This is a commercial model, if installed in a residence
some commercial service companies may not be able
to service it on site.
The manufacturer has designed and produced this
machine with the finest in materials. The manufacturer
assumes no liability for units that have been altered in
any way. Alterations or part substitutions will void the
warranty. Specifications and designs are subject to
change without notice.
Options:
There are two floor mounting kits available:
• KUFM15: for 15” models
• KUFM20: for 20” model
Important Details