MC0322 through MC2148
Air, Water, and Remote Cooled Service Manual
January 2022
Page 65
Repair Section
Purge valve
1.
Push and hold the Off button to shut the machine off.
2. Disconnect electrical power.
3. Remove front panel.
4. Remove left side panel.
5. Unplug wires from valve coil.
Note: The coil can be removed from the valve body by rotating it 1/8
turn CW. After removal of the coil the spring and plunger can be taken
out.
6. Remove screws holding valve to mounting bracket.
7. Remove inlet and outlet hoses
8. Remove valve from cabinet.
9. Reverse to reassemble
10. Push and release the On button to restart the machine
Water level sensor
1.
Push and hold the Off button until the machine shuts off.
2. Remove the front panel.
3. Locate water level sensor.
4. Squeeze the locking tabs together and pull the sensor
up and out of the sump.
5. Unplug the electrical connection from the sensor.
6. Reverse to reassemble
Electrical Shock Hazard
Disconnect electrical
power before beginning