FOR THE ELECTRICIAN
CONFORM TO ALL APPLICABLE CODES
The electrical power to the unit is supplied
through the junction box at the rear of the
machine.
Check the nameplate (located on the back
panel) for the voltage requirements, and
for the minimum circuit ampacity. The
machine requires a solid chassis to earth
ground wire.
The ice maker should be connected to its
own electrical circuit so it would be
individually fused. Voltage variation must
remain within design limitations, even
under starting conditions.
Electrically the remote condenser fan
motor is connected to the icemaker at the
contactor terminals for the compressor
and the fan motor operates whenever the
compressor operates.
Electrical connections are made at the
junction box at the back of the icemaker
and at the junction box on the remote
condenser.
The remote condenser must be wired to
the icemaker in accordance with local and
national electrical codes with a minimum
of 18 Awg. wire with an ground bonding
wire connected to the ground screws
provided in both the condenser and
machine field wiring boxes. All outdoor
wiring must be in rainproof conduit.
All external wiring must conform to
national, state, and local electrical
codes. The use of a licensed
electrician is required to perform the
electrical installation.
NME1254R & FME1504R
January 2000
Page 9
REMOTE CONDENSER
WATERPROOF
(LIQUID TIGHT)
CONDUIT
ICEMAKER
JUNCTION BOX
POWER
SUPPLY