MAINTENANCE
1. The bin control uses devices that sense light,
therefore they must be kept clean enough so that
they can "see". At least twice a year, remove the
bin control sensors from the base of the ice chute,
and wipe the inside clean, as illustrated.
2. The ice machine senses water level by a probe
located in the water reservoir. At least twice a
year, the probe should be removed from the
reservoir, and the tip wiped clean of mineral
build-up.
3. The bearing in the breaker should also be
checked at least two times per year.
Check the bearing by:
•
pushing the bail clamp back and removing the
ice chute cover
•
unscrewing the ice sweep
•
unscrewing the breaker cover
•
unscrewing the auger stud
Inspect the assembly, looking for wear.
See Removal and Replacement to replace bearing
or seals. Reverse to reassemble.
4. Check and tighten all bolts and screws.
BREAKER
COVER
CLEAN THE ICE
LEVEL CONTROL
SENSORS
RESERVOIR
CLEAN THE
WATER LEVEL
SENSOR
/////////////////////////////
CAUTION: THE
TIMP IS MADE OF
GLASS
///////////////////////////////
SLIDE ICE
LEVEL
CONTROLS OUT
OF CHUTE
ICE SWEEP
Electrical Shock Hazard
Electrical shock can cause
personal injury.
Disconnect electrical
power before beginning.
Single System RL
January 1997
Page 14