Page 11
Page 11
G. INSTALLATION PRACTICE
1.
Hand shut-off valve
2.
Water filter
3.
Water supply line (flexible hose)
4.
3/4" male fitting
5.
Vented drain
6.
Open trapped vented drain
7.
Drain fitting
8.
Main switch
9.
Power line
WARNING. This icemaker is not designed for outdoor installation and will not function in
ambient temperatures below 10
°
C (50
°
F) or above 40
°
C (100
°
F).
This icemaker will malfunction with water temperatures below 5
°
C (40
°
F) or above 35
°
C
(90
°
F).
1
2
3
4
5
6
7
8
9
5.
Has the voltage been tested and checked
against the data plate rating?
6.
Has the water supply pressure been
checked to ensure a water pressure of at
least 1 bar (14 psi).
7.
Check all refrigerant lines and conduit
lines to guard against vibrations and possible
failure.
8.
Have the bolts holding the compressor down
been checked to ensure that the compressor is
snugly fitted onto the mounting pads?
9.
Have the bin liner and cabinet been wiped
clean?
10. Has the owner/user been given the User
Manual and been instructed on the importance of
periodic maintenance checks?
11. Has the Manufacturer’s registration card
been filled in properly? Check for correct model
and serial number against the serial plate and
mail the registration card to the factory.
12. Has the owner been given the name and the
phone number of the authorized SCOTSMAN
Service Agency serving him?