BEARING MAINTENANCE
The top bearing in the breaker should also be
checked at least
two times per year
.
Check the breaker bearing by:
·
removing the ice chute cover
·
unscrewing the ice sweep
·
removing the water shed and the breaker cover
(left hand thread)
·
unscrewing the auger stud
Inspect the bearing. There should be plenty of
grease in sight. If grease is needed the bearing
and breaker should be removed to check the
action of the bearing. It should rotate smoothly.
To remove the breaker take out all four allen head
cap screws and pull the breaker off the auger and
evaporator.
If the bearing only needs grease, inject grease into
the bearing using Scotsman grease needle pn
02-3559-01 and Scotsman bearing grease
cartridge, pn A36808-001. Be sure to inject grease
evenly and thoroughly.
See Removal and Replacement section to replace
bearing or seals.
Reverse to reassemble.
Double System RL
November 2000
Page 16
Chute Cover
Ice Sweep
Off
Breaker Cover
Auger Stud
Cap Screw
Grease
Needle, part
number