Evaporator Thermistor
• Typically triggers timer at about 3.3 degrees F.
– 76,790 ohms
• If thermistor is out of range, open or shorted
controller operates on preset freeze and harvest
times
– Signal of evaporator thermistor failure is
all green
lights on controller blink together
– Timed cycles may make ice too thick or too thin