Correct Settings
• Bridge Thickness
– Must release ice as a unit, bridge will be about 3/16
inch and there will be a hollow part in the cube
• Harvest Time
– Must continue long enough to release the ice, plus
10 to 20 seconds more.
– Water fills during harvest, short harvest may increase
scale build up
• Add time if needed to reduce scale build up
• 90 seconds is suggested minimum time in typical water