Coupling Instructions
The couplings on the ends of the pre-charged line
sets are self-sealing when installed properly.
Follow these instructions carefully.
These steps must be performed by an EPA
Certified Type II or higher technician.
Initial Connections
1. Remove the protector caps and plugs. Wipe the
seats and threaded surfaces with a clean cloth to
remove any possible foreign matter.
2. Lubricate the inside of the couplings, especially
the O-rings, with refrigerant oil.
3. Position the fittings on the correct connections
on the condenser and ice machine.
•
The
1
2
²
discharge line (schrader valve end)
goes to the remote condenser fitting marked
“discharge line”.
•
The
3
8
²
liquid line (schrader valve end) goes
to the remote condenser fitting marked
“liquid line”.
•
The
1
2
²
discharge line goes to the ice maker
fitting marked “discharge line”.
•
The
3
8
²
liquid line goes to the ice maker
fitting marked “liquid line”.
Final Connections:
4a. Begin by tightening the couplings together by
hand until it is certain that the threads are properly
engaged.
4b. Then using two wrenches tighten the coupling
until it bottoms out or a definite increase in
resistance is felt.
It is important that ONLY the nut on the
pre-charged tube be turned, or the diaphragms will
be torn out by the piercing knives and they will be
loose in the refrigeration system.
Note: As the couplings are tightened, the
diaphragms in the quick connect couplings will
begin to be pierced. As that happens, there will be
some resistance to tightening the swivel nut.
4c. Continue tightening the swivel nut until it
bottoms out or a very definite increase in
resistance is felt ( no threads should be showing).
5. Use a marker or pen to mark a line on the
coupling nut and unit panel. Then tighten the
coupling nut an additional one-quarter turn. The
line will show the amount that the nut turns. Do
NOT over tighten.
6. After all connections have been made, and after
the king valve has been opened (do not open yet),
check the couplings for leaks.
CME506R, 656R, 806R: AutoIQ Cubers
January 2000
Page 8
Tighten Swivel Nut
Rotate Swivel Nut ¼ Turn More
Clean and Lubricate Couplings
Summary of Contents for CME506R
Page 42: ......