Removal and Replacement
Drain Tubing
1. Remove the front panel.
2. Push and release the Off button.
3. Remove bin baffle.
4. Remove 1 plastic bolt and the reservoir cover.
5. Unplug water pump, disconnect ground wire.
6. Unplug water level sensor.
7. Lift pump up slightly and pull discharge hose
from pump.
8. Remove pump and water level sensor from
ice machine.
9. Pull up and forward to remove standpipe.
10. Disconnect back of cabinet drain system.
11. Remove nut on inside of reservoir (where
standpipe was).
12. From inside the bin, pull drain tube out of
the reservoir and down. Remove from machine.
13. Reverse to reassemble.
CME506R, 656R, 806R: AutoIQ Cubers
January 2000
Page 36
Water Sensor
Standpipe
Note: Standpipe height is critical.
Measured from the top of the
standpipe to the top of the reservoir,
the distance should be 2
5
8
". If not,
adjust it by rotating the top of the
standpipe (it is on threads) to obtain
that distance.
Water Level Sensor/Float Stem
1. Disconnect the electrical power.
2. Remove the front panel.
3. Remove 1 plastic bolt and the reservoir cover.
4. Pull float ball from float stem (it is a snap fit). Pull
stem out.
5. Locate water level sensor mounting tabs,
compress together to release sensor from bracket.
6. Remove harness from sensor.
7. Reverse to replace.
Note: Float stem slot opening is 2".
8. Replace front panel.
9. Re-connect electrical power.