Specifications
Both of these ice machines are designed to be
installed indoors, in a controlled environment.
They can operate satisfactorily under a wide
variety of conditions. However, Do NOT operate
the machine in temperatures it has not been
designed for. Do NOT operate the machine above
or below the voltage limits for the particular model.
Do NOT operate the machine with too little or too
much water pressure.
Operational Limits
Minimum
Maximum
Air Temperature
50
o
F.
100
o
F.
Water Temperature
40
o
F.
100
o
F.
Water Pressure
20 psi
80 psi
Voltage (60 Hz)
197
253
Voltage note:
The control system transformer in
the control box of this ice machine has two
primary taps, one for 208 volt power and one for
240 volt power. The machine ships with the power
supply connected to the 208 volt tap. Change to
the 240 volt tap when the voltage supplied to the
unit is greater than 229 volts.
Scotsman reserves the right to make design
changes and/or improvements at any time.
Specifications and designs are subject to change
without notice.
Scotsman assumes no liability or responsibility of
any kind for products manufactured by Scotsman
that have been altered in any way, including the
use of any parts and/or other components not
specifically approved by Scotsman.
Bins:
All models will fit a standard, 48" wide or wider
open top Scotsman Ice Storage Bin. Some
examples are:
•
BH900
•
BH1100
•
BH1300
•
BH1600
In addition, there may be other bins that can be
used, check Scotsman’s sales literature for
application information.
Note: Slope-front bins must have an internal baffle.
Scotsman’s BH900 haas the required baffle. Baffle
must be approximately in the position shown in the
diagram below.
Model Number
Dimensions
W x D x H
(w/o bin)
Basic Electrical
(volts/Hz/phase)
Use
Condenser
Refrigerant
Charge
R-404A
Minimum
Circuit
Ampacity
Maximum
Fuse Size
CME2006RS-32C
48 ½ “ x 24" x 28 208-230/60/1
ECR611-32A
336 oz
30
40
CME2006RS-3C
same
208-230/60/3
ECR611-32A
336 oz
20
30
* The remote condenser is designed to work in temperatures from -20
o
F. to 120
o
F.
Use precharged tubing kits,
LRTE25
(25’) or
LRTE40
(40’) or
LRTE75
(75’). Select the length closest to
the needs of the particular installation. NOTE: These line sets have a
larger diameter discharge
line than
line sets for smaller Scotsman remote systems and are the only line sets that may be used with this product.
The stacking kit required to place two like model cubers together is:
KSCME6-LG-B.
BASIC INFORMATION
12.0"
4.0"
Side View
Baffle
CME2006R
November 2004
Page 2