Specifications
This ice machine is designed to be installed
indoors, in a controlled environment. It will operate
satisfactorily under a wide variety of conditions. Do
NOT operate the machine in temperatures it has
not been designed for. Do NOT operate the
machine above or below the voltage limits for the
particular model. Do NOT operate the machine
with too little or too much water pressure.
Operational Limits
Minimum
Maximum
Air Temperature
50
o
F.
100
o
F.
Water Temperature
40
o
F.
100
o
F.
Water Pressure
20 psi
80 psi
Voltage (60 Hz model) 198
253
Voltage (50 Hz model) 207
253
Inlet water flow required is 2.7 GPM.
All models will fit a standard, 30" wide Scotsman
Ice Storage Bin. Some examples are:
•
BH550
•
HTB555
Note: Slope front bins must have an internal baffle.
Scotsman BH550 and HTB555 have the required
baffle. Baffle must be approximately in the position
shown in the diagram on page 5.
In addition, there may be other bins that can be
used, check Scotsman’s sales literature for
application information.
Kits:
•
BH800 bin: Add kit
KBT23
•
BH900 bin: Add kit
KBT22
•
ID200 or ID250 Dispenser: Add adapter kit
KBT44. Do not deploy the CME1056’s
thermostat.
•
Lancer 30” wide dispenser. Add adapter kit
KSTAT-MD
•
Cornelius ED200 dispenser requires adapter
kit from Cornelius. Do not deploy the
CME1056’s thermostat.
•
Other combinations may be available. See
Scotsman product literature for more
information.
•
Stacking two CME1056s together requires
stacking kit:
KSCME6-MD
(cannot stack any
other model with a CME1056).
Scotsman reserves the right to make design
changes and/or improvements at any time.
Specifications and designs are subject to change
without notice.
Scotsman assumes no liability or responsibility of
any kind for products manufactured by Scotsman
that have been altered in any way, including the
use of any parts and/or other components not
specifically approved by Scotsman.
CME1056
May 2002
Page 2
Model Number
Dimensions
W" x D" x H"
(w/o bin)
Basic
Electrical
Condenser
Type
Minimum
Circuit
Ampacity
Maximum
Fuse Size
Refrigeran
t Charge
(R-404A)
CME1056AS-32F
30 ½ x 24 x 28 208-230/60/1
Air Cooled
18.75
20
44 ounces
CME1056WS-32F
same
208-230/60/1
Water Cooled 17.25
20
28 ounces
CME1056AS-3F
same
208-230/60/3
Air Cooled
13.63
15
44 ounces
CME1056WS-3F
same
208-230/60/3
Water Cooled 12.13
15
28 ounces
CME1056AS-6F
same
230/50/1
Air Cooled
44 ounces
CME1056WS-6F
same
230/50/1
Water Cooled
28 ounces
Basic Information