Page 5
FIGURE 2
3.1 CONTROL PANEL FUNCTIONS
SEE FIGURE 2 BELOW.
The control panel consists of four switches.
The MAIN DISCONNECT SWITCH (A) turns the power off to the control panel.
The STOP switch (D) stops the bundle loader functions but does not kill the power to the control panel.
This switch is a maintained switch and it must be manually pulled out each time it is depressed.
The START button (C) starts the loader functions.
The panel will not energize unless the selector switch (B) is in the START position.
The selector switch (B) is a three position switch.
It has a START position in the middle and it must be in this position to start the machine.
The FEED DOWN position relaxes the loading straps and the FEED UP position tightens them.
3.0 SET-UP
A
C
B
D
START
UP DOWN
EMERGENCY
STOP
POWER
UP