![Scorpio SR-i800 Installation Manual And User'S Manual Download Page 4](http://html1.mh-extra.com/html/scorpio/sr-i800/sr-i800_installation-manual-and-users-manual_1218221004.webp)
Note: Once an alarm trigger has occurred and the siren duration is completed, the system will remain
armed and accept any additional triggers.
Components List
MCM (Main Control Module)
*
Remote Transceiver
Generic Installation Kit (GEN-1)
Accessory Harness (ACC-1)
Main Harness (HAR-1)
RFID Module
*This remote transceiver uses a CR2032 battery. To replace the battery, pry the cases
apart using a flathead screwdriver at the small end of the remote. Then slide the
screwdriver towards the button until the case halves come apart. Now pull the circuit
board out of the rear case half and replace the battery. Last part is to snap the circuit
board back into the rear case and the two case halves back together and you’re done.
Planning the Installation
It is very important that before starting the installation of the security system, you carefully
read the installation instructions and spend time planning the installation. By planning
ahead, you will be able to select the best approach in placing, securing and wiring the
system to your specific motorcycle. Although the installation is not difficult, there are a
number of steps that must be taken for the system to operate properly. We suggest you
read the steps on the following page.
3
Alarm Triggers
1. If the bike is shocked, the siren will sound for 5 seconds and the turn signal lights will flash.
2. If the bike is tilted, the siren will sound for 30 seconds and the turn signal lights will flash.
3. If the ignition switch is turned on with the remote not present, the siren will sound for 30
seconds and the turn signal lights will flash.
Manual Override Procedure
Programming Personal Override code
A personal override code will be a sequence of left – right – left - right turn signal flashes
that can be used if the remote is lost to disable the alarm:
Enter Programming Mode
1.
Manually disarm system by quickly double pressing the remote button.
2.
(From the off position) - Turn ignition on – off – on – off – on.
3.
Press and hold the button until the siren chirps 3 times.
Select number of flashes for the Manual Override Code
The code will be a combination of left-right-left-right turn signal counts.
1.
Turn on left turn signal to desired number of flashes. (up to 9)
2.
Turn on right turn signal to desired number of flashes. (up to 9)
3.
Turn on left turn signal to desired number of flashes. (up to 9)
4.
Turn on right turn signal once to exit mode. (Will only register one flash.)
5.
The bike will flash the code in the same sequence entered.
*This feature is not compatible with every motorcycle on the market.
*Some bikes are easier than others to program and operate this
feature, make sure to test the code once it is programmed.
Using the Manual Override Code in case of lost remote or if the battery is depleted
1.
Turn ignition key to the on position. Let alarm go thru a full cycle until the turn
signal lights stop flashing. (If siren is turned off, you do not need to wait for a full
cycle)
2.
Enter the Manual Override Code as originally programmed.
3.
When correct code is entered, the alarm will deactivate.
8