background image

The units described in these instructions are for use in a Standard UK Plug Socket, 
they also feature a Standard UK Plug Socket on the front side of the product. 

In the case of the RFRP-20, the front socket is provided as an additional socket 
for convenience. The socket must remain switched on at all times in order for the 
repeater to remain operational.

Supply Voltage: 

  230V~

Frequency: 

 868MHz

Minimum control distance: 

  20mm

Range uninterrupted: 

  200M

Ingress protection: 

  IP20

Dimensions: 

  60 x 120 x 80mm

Applicable standards: 

  EN607 30-1 ED.2

The Signal Repeater will extend the range between transmitters and receivers by up to 200M in free-air, and offer a solution in the 
event building materials restrict the original signal sent. See the installation guidance notes supplied with this device. 

Notes: 

If more than one repeater is required for the same transmitter, the installer must ensure the signal going through the additional 
repeaters does not transmit to the same receiver. This may confuse the receiver and cause false activation. To resolve the issue, 
remove the pairings from additional repeaters, see section 3a below.

WARNING!

Please read through these steps before attempting to use the unit. 

The instructions feature steps that must be carried out in quick succession. 

An awareness of the steps beforehand will make this process easier.

Before you start; make sure all 
receivers in the vicinity are in their 
“off” state. Any receivers left on may 
interfere with the programming of 
the repeater.
Plug in the unit with the socket 
power off.

While holding the “Status/Prog” 
button, switch on the socket. 
Continue holding the “Status/Prog” 
button until the red indicator light 
shows. Release the button. The 
indicator light will flash green.

While the green light is flashing 
press the “Status/Prog” button 
again. The light should now 
flash red for 5 seconds then no 
light will appear. This indicates 
the unit is in “Learning Mode”.

To Remove Pairings

: (following on from step 3) If you press the “Status/Prog” button again, while the red light is flashing, it will clear 

any stored pairings. The red light will illuminate for 5 seconds then clear, once all lights are off, press the “Status/Prog” button again to 
confirm.

3a 

Programming / Learning Mode

RFRP-20 - Signal Repeater 

1

2

3

Signal Range

Any device with the signs of damage and/or missing parts should NOT be installed and 

should be returned to the seller.

Please refer to ‘Installation Guidance Notes’ supplied with the range of receiver before 

commencing with the installation.

Devices are designed to be mounted internally only.

www.click-smart.com