REQUIRED PARTS

(1)

Xwire SmartBezel Adapter
SCK Part No. 231-60206-01

(2)

Self-tapping Connectors (included)
SCK Part No. 141-51026
Qty. 2

INSTALLATION

1.

Locate wires numbered 1 and 3 in the 9-pin connector on
the FAST VC-210 or FAST EM-99 controllers.

2.

Clamp self-tapping connector to these wires to provide a
24VAC output for the SmartBezel.

3.

Connect the two spade terminals to the pair coming from
the SmartBezel.

4.

Connect the 3-pin Molex connector on the SmartBezel to
the 3-pin Molex on the controller.

5.

Position the SmartBezel onto the
front of the FAST Controller.
Carefully place the five SmartBezel
wires into the channel on the
FAST Controller.

6.

Install the FAST Controller on the
fryer and verify the LED sequence
is correct per your application by
referring to the charts on page 6.

The FAST Controller is now ready to be used as an SCK Xwire
wireless device.

STEP 2

The SmartBezel Adapter

Summary of Contents for Xwire SmartAdapter

Page 1: ...ances XwireTM SmartBezel Adapter for Process Controllers XwireTM SmartGateway PC Adapter SmartAdapter SmartBezel SmartGateway 24 7 Toll Free Technical Support 1 866 840 4271 from the U S Canada and th...

Page 2: ...Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment genera...

Page 3: ...No 141 15734 INSTALLATION 1 Connect USB cable to the communication port on the SmartGateway 2 Power off the PC and connect the SmartGateway to an available USB port using the USB cable NOTE It s impor...

Page 4: ...these wires to provide a 24VAC output for the SmartBezel 3 Connect the two spade terminals to the pair coming from the SmartBezel 4 Connect the 3 pin Molex connector on the SmartBezel to the 3 pin Mol...

Page 5: ...Part No 222 50702 01 ii SCK Part No 222 50701 01 iii SCK Part No 222 50701 02 D Velcro Brand Fastener If something is missing please call 1 866 840 4271 8 00 a m 5 00 p m EST INSTALLATION 1 Pull the S...

Page 6: ...two light bars are lit RED WEAK Only one light bar is lit RED NONE No light bars are lit RED STATUS LED CHART SIGNAL STRENGTH INDICATORS LIGHT BARS The SCK Xwire status indicator consists of three co...

Page 7: ...Changing the Default PAN ID Personal Area Network Identification The factory default PAN ID is 1 Should your SCK Xwire device experience interference that prevents it from working properly the network...

Page 8: ...CK Wireless XwireTM SmartGateway SCK Wired Backbone For additional information on any of these accessories or to request Technical Specification Sheets please contact your SCK Representative or contac...

Reviews: