SciQuip Oven-110S User Manual Download Page 3

1.Key features

2.Technical Specifications

3.Control Panel

4.Preparation and Start-up

5.

Switch between operating modes

6.

Settings for Program control mode

8.Setting and Application of other functions

.Operation and Switch off

10.Electric theorem

11.Normal Malfunction and Debugging

Setting of  parameter under the

 constant temperature control mode

7.

9

7.

8.Setting and Application of other functions

Table of contents

1.Key features

1.Individualized 10 segments, 18-step preset programmes achieve temperature preset timing 

programs or reciprocating, stepped, ladderlike temperature running.

2.Sound heat insulation design and the transparent glass door meet European security 

standard.

3.Automatic poweron and poweroff, timing operation, clock indicating, poweroff recovery, 

parameter recalling and encryption, temperature indicating and correcting, RS-232 interface 

and built-in microprinter.

4.Monitoring timer, independent exceeding guard, over temperature protector(adjustable). 

5.Independent protector for electric leakage and over current.

6.Self-diagnosed techniques, such as power cut alarm, sensor failure alarm, and upper and 

lower temperature limit exceeding alarm.

7.Highly responsive thermal sensor and environmental scanning microprocessor chip.

8.Three-dimensional heating technology ensures the solid temperature uniformity in the 

working chamber.

9.Sound airway structure and gentle airflow circulation design.

10Unique design of chamber guaranties the cleanliness of the sample.

11.Mirror stainless steel chamber, electro polished stainless steel shelves and toughened 

glass internal door.

12.The luxurious and elegant profile with aesthetic designing.

1

Summary of Contents for Oven-110S

Page 1: ...This Manual applies to Please read thisGuide attentively beforeusing and be careful of keepingthe Manual incase of contingentuse User s Manual Oven S Series Blast Air Oven...

Page 2: ...ire cause by electric leakage 9 5 When moving the equipment Moving the equipment connected with power supply will probably result in electric shock Danger Warnings against likely injury or death Pleas...

Page 3: ...ration clock indicating poweroff recovery parameter recalling and encryption temperature indicating and correcting RS 232 interface and built in microprinter 4 Monitoring timer independent exceeding g...

Page 4: ...eating indicator Actual Temperature indicator Time indicator Operating status indicator Setted Temperature Indicator Status keeping indicator Refrigeration indicator Operating button R H S R H S SET S...

Page 5: ...status indicator When the equipment is well functioned this indicator will be light Status keeping indicator Under program control mode when the equipment is in the state of temperature keeping this...

Page 6: ...nfirm The Ramp End Temperature RET and Hold Time HT of each segment can be set in the same way Each segment contains 3 parameter settings RT RET HT 6 Setting of parameter under the constant temperatur...

Page 7: ...ram press the R H S and hold for 3 seconds to quit the existing program first the Run indicators goes off and press R H S again to restart the whole program Case B HSD 0 1 Attention 2 SET SET SET SET...

Page 8: ...2 Setting of the clock Press the SET key and enter the password 4 The clock time can be changed when deviation between clock time and standard time occurs Press the SET key and enter the password 4 Pr...

Page 9: ...igned programme the operating indicator RUN turns on 2 When the equipment is in the state of temperature control or programme control the heating indicator lights or twinkles means the heating is conn...

Page 10: ...arameter is unreasonable Refer to the operating procedure and change or re set parameter 3 Malfunction of heating system occurs Notify the manufacturer for repair service Real temperature is lower tha...

Reviews: