background image

User Manual

Scion Tech

SC04.MX44+

8.8 Network Settings

The network settings page allows the configuration of the network settings.

Status

4 x 4 HDMI Matrix

Admin

Log Out Standby

IP Settings

Video

Input

Output

Network

System

Page 11

Tel: +44 (0) 1635 862484

www.scion-tech.co.uk

[email protected]

Mode

Static

DHCP

IP Address:

192.168.1.100

Subnet Mask:

255.255.255.0

Gateway:

192.168.1.1

Telnet Port:

23

Web Login Settings

User

Admin

Old Password:

New Password:

Username:

Confirm:

8.9 System

The system page allows changes to the front panel functions and RS232 baud rates. This page is also used to
perform upgrades and system reset to factory default.

Status

4 x 4 HDMI Matrix

Admin

Log Out Standby

Panel Lock

Video

Input

Output

Network

System

ON

OFF

Serial Baud Rate

Browse…

Factory Reset:

Reboot:

Firmware Update

Beep (sound)

ON

OFF

115200

9600

19200

38400

57600

4800

Update

Reset

Reboot

Summary of Contents for SC04.MX44+

Page 1: ...User Manual Version 1 0 SC04 MX44 User Manual Scion Tech SC04 MX44 Tel 44 0 1635 862484 www scion tech co uk sales scion tech co uk 18Gbps 4 x 4 HDMI Matrix Switch with ARC and Downscaler...

Page 2: ...protection systems is highly recommended in order to protect and extend the life of your equipment Contents 1 Introduction 2 2 Product Features 2 3 Package Contents 2 4 Specifications 3 5 Front Rear P...

Page 3: ...ction copy and built in standard settings ensuring compatibility with all source and sink devices The matrix is controlled with switches located on the front panel IR remote control RS232 and TCP IP w...

Page 4: ...12 bit Output Scaling 4K 1080P HDMI Audio PCM2 0 5 1 7 1CH Dolby Digital Plus EX Dolby True HD DTS DTS EX DTS 96 24 DTS High Res DTS HD Master Audio DSD Coaxial Audio PCM2 0 Dolby Digital Plus DTS 2...

Page 5: ...e input source Page 4 Tel 44 0 1635 862484 www scion tech co uk sales scion tech co uk IR OUT 1 4 2 3 1 OUT 2 4 2 3 1 OUT 3 4 2 3 1 OUT 4 4 2 3 1 18Gbps 4 x 4 HDMI Matrix www scion tech co uk SCION 1...

Page 6: ...on tech co uk sales scion tech co uk Button Function Description Power ON and Standby Output 1 4 Selects input source to outputs Selects the next or last input SD Activates the downscaler HDMI Matrix...

Page 7: ...The default IP address is 192 168 1 100 Note If the IP address is unknown use the RS232 interface command in section r ip addr to discover the current IP settings or reset the matrix to it s factory...

Page 8: ...ales scion tech co uk User Manual Scion Tech SC04 MX44 8 1 Status Status Video Input Output Network System 4 x 4 HDMI Matrix Admin Log Out Standby Status Model SC04 MX44 Firmware Version V1 00 04 1 37...

Page 9: ...Name Preset Set Preset Save Preset Clear Preset 1 Preset 2 Preset 3 Preset 4 Save Set Set Set Set Clear Save Save Save Clear Clear Clear 8 3 Input The input page provides information about which input...

Page 10: ...eo Audio 2 0 4K2K60Hz_420 Dolby DTS 5 1 4K2K60Hz_420 HD Audio 7 1 4K2K60Hz_444 Stereo Audio 2 0 4K2K60Hz_444 Dolby DTS 5 1 4K2K60Hz_444 HD Audio 7 1 4K2K60Hz_444 Stereo Audio 2 0 HDR 4K2K60Hz_444 Dolb...

Page 11: ...2 Output 2 HDMI 4K 1080p Output 3 Output 3 HDMI Auto Output 4 Output 4 HDMI Auto ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF 8 6 Resolution Scaling The following options are available Bypa...

Page 12: ...Subnet Mask 255 255 255 0 Gateway 192 168 1 1 Telnet Port 23 Web Login Settings User Admin Old Password New Password Username Confirm 8 9 System The system page allows changes to the front panel funct...

Page 13: ...lt Data bits 8 Parity None Stop bits 1 Note 1 All messages sent to the matrix must be terminated with an exclamation mark Any carriage return that is present after the end of the command will be ignor...

Page 14: ...anel button z 0 1 z 0 lock off z 1 lock on Panel button lock on panel button lock off r lock Get panel button lock state Panel button lock on off s save preset z Save switch state between all output p...

Page 15: ...30Hz_444 Dolby DTS 5 1 12 4K2K30Hz_444 HD Audio 7 1 13 4K2K60Hz_420 Stereo Audio 2 0 14 4K2K60Hz_420 Dolby DTS 5 1 15 4K2K60Hz_420 HD Audio 7 1 16 4K2K60Hz_444 Stereo Audio 2 0 17 4K2K60Hz_444 Dolby D...

Page 16: ...Set network gateway Set Gateway 192 168 1 1 Please use s net reboot Command or re power device to apply new config DHCP on device can t config gateway set DHCP off first r gateway Get network gateway...

Page 17: ...1635 862484 www scion tech co uk sales scion tech co uk HDMI Source 1 4 Display Display Display Display IN 1 IN 2 IN 3 IN 4 DC 5V OUT 1 OUT 2 OUT 3 OUT 4 OUT 4 COAX L R OUT 3 COAX L R OUT 2 COAX L R O...

Page 18: ...rking condition Warranty If your product does not work properly because of a defect in materials or workmanship our Company referred to as the warrantor will for the length of the period indicated as...

Page 19: ...HERE ARE NO EXPRESS WARRANTIES EXCEPT AS LISTED UNDER LIMITED WARRANTY COVERAGE THE WARRANTOR IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE USE OF THIS PRODUCT OR ARISING OU...

Reviews: