background image

5 OF 7 

the bottom of the tank 

Increased pump noise 

Cavitation occurring 

Reduce suction pressure 

Irregular 

functioning 

of 

the 

by-pass 

Dispense  fluid  until  the  air  is 

purged from the by-pass system 

Leakage from the pump body 

Diaphragm damaged   

Check and replace the diaphragm   

 

H. MAINTENANCE 

All models are designed and constructed to require minimal maintenance. 

In any case always bear in mind the following basic recommendations for maintenance: 

On a weekly basis, check that the tubing joints have not loosened, to avoid any leakage. 

On a monthly basis, check the pump body and keep it clean of any impurities. 

On a weekly basis, check and keep clean the line suction filter. 

On a monthly basis, check that the electric power supply cables are in good condition. 

I. NOISE LEVEL 

Under normal working conditions the noise emission from all models does not exceed the valve of 

75 db at a   

distance of 1 meter

 from the electric pump. 

J. DISPOSING OF CONTAMINATED MATERIALS 

In the event of maintenance or demolition of the machine, do not disperse contaminated parts into the 

environment.   

Refer to local regulations for their proper disposal. 