background image

1

BlueSpin

 (Hotplate) Magnetic Stirrer

Preface 

Welcome to the “

BlueSpin

 (Hotplate) Magnetic Stirrer”. 

Users should read this Manual carefully, follow the 
instructions and procedures, and be aware of all the 
cautions when using this instrument.   

Service 

When help needed, you can always contact the Service 
Department of manufacturer for technical support in the 
following ways: 

SCILOGEX, LLC 

500 Four Rod Road 
Suite 122 
Berlin, CT 06037 USA 
Tel: 1-860-828-5289 
Fax: 1-860-828-5389 
E-mail: 

[email protected]

 

Http://www.scilogex.com 

Please provide the customer care representative with the 
following information

 

• Serial number

on the rear panel

Certification

• Description of problem (i.e., hardware or software)
• Methods and procedures adopted to resolve the problems
• Your contact information

Warranty 

This instrument is warranted to be free from defects in 
materials and workmanship under normal use and service, 
for a period of 24 months from the date of invoice. The 
warranty is extended only to the original purchaser. It shall 
not apply to any product or parts which have been damaged 
on account of improper installation, improper connections, 
misuse, accident or abnormal conditions of operation. 
For claims under the warranty please contact your local 
supplier. You may also send the instrument directly to 
manufacturer, enclosing the invoice copy and by giving 
reasons for the claim.

Summary of Contents for MS-H280

Page 1: ...H280 Pro BlueSpin LED Digital Hotplate Magnetic Stirrer MS PA BlueSpin LED Digital Magnetic Stirrer MS PB BlueSpin Classic Magnetic Stirrer Please read the User Manual carefully before use and follow all operating and safety instructions www scilogex com 12300175 ...

Page 2: ...tems 4 4 Control 4 4 1 Control elements 4 4 2 Display 7 5 Trial Run 8 6 Function Heating Digital hotplate model 8 6 1 Working with external temperature sensor 9 6 2 Residual heat warning HOT 9 7 Stirring 10 8 Faults 10 9 Maintenance and Cleaning 11 10 Associated Standards and Regulations 11 11 Specifications 12 12 Ordering Information 14 ...

Page 3: ...ng information Serial number on the rear panel Certification Description of problem i e hardware or software Methods and procedures adopted to resolve the problems Your contact information Warranty This instrument is warranted to be free from defects in materials and workmanship under normal use and service for a period of 24 months from the date of invoice The warranty is extended only to the ori...

Page 4: ...res with hazardous substances or under water Gradually increase the speed reduce the speed if Stirring bar breaks away due to high speed The instrument is not running smoothly or container moves on the base plate Temperature must always be set at least 50 lower than the fire point of the media used Be aware of hazards due to Flammable materials or media with a low boiling temperature Overfilling o...

Page 5: ...s not touch the hotplate Do not cover the device The instrument may only be opened by experts Keep away from high magnetic field 2 Proper Use The instrument is designed for mixing and or heating liquids in schools laboratories or factories Observe the minimum distances between the devices between the device and the wall and above the assembly min 100 mm Figure 1 This device is not suitable for usi...

Page 6: ...er for technical support Note If there is any apparent damage to the system please do not plug it into the power line 3 2 Listing of Items The package includes the following items Items Qty Main unit 1 Power cable 1 Stirrer bar 1 User Manual 1 Table 1 4 Control 4 1 Control elements Speed Control Knob LED Display Temperature Control Knob Hotplate model Probe Hotplate model Figure 2 Digital hotplate...

Page 7: ...5 BlueSpin Hotplate Magnetic Stirrer Speed Control Knob LED Display Figure 3 Digital model Speed Control Knob Figure 4 Classic model Figure 5 ...

Page 8: ...l working state and all settings Probe When the external temperature sensor PT1000 is plugged in probe icon is lit Power Switch Switch ON or OFF the instrument Digital model Temperature Control Knob Stir Set the rotary speed The function Stirring is switched ON or OFF via push ON OFF knob LED Display LED displays the real working state and all settings Power Switch Switch ON or OFF the instrument ...

Page 9: ...tplate temperature is still above 50 C LED displays Hot otherwise LED displays OFF Speed display area When stirring function was switched ON LED displays the speed setting value and flashes The setting value does not flash until real speed reaches the set point Table 3 Figure 7 Digital model Characters Descriptions Speed display area When stirring function was switched ON LED displays the speed se...

Page 10: ...rking 6 Function Heating Digital hotplate model The device is controlled by digital temperature control technology which has two separate safe circuits The hotplate is kept at a constant temperature by a digital control circuit The hotplate temperature can also be monitored from a separate adjustable safe circuit The two temperature sensors internal for temperature control are built into the hotpl...

Page 11: ...ly under abnormal conditions Please operate follow the instructions below Switch OFF the instrument Ensure the external temperature sensor is inserted in the media heated Switch ON the instrument and run heating function If the heating function does not work please contact manufacturer supplier for technical support 6 2 Residual heat warning HOT In order to prevent the risk of burns from a hotplat...

Page 12: ... power ON Check whether the power line is unplugged Check whether the fuse is broken or loose Fault in power on self test Switch OFF the unit then switch ON and reset the instruments to factory default setting Stir speed cannot reach set point Excessive medium viscosity may cause abnormal speed reduction of the motor Unit cannot be powered off when switched off Check if the residual heat warning f...

Page 13: ...nufacturer that this method will not harm the instrument Wear the proper protective gloves during cleaning of the instrument Note Electronic device can not clean with cleanser If you require maintenance service must be cleaned the instrument in advance to avoid pollution of hazardous substances and to send back into original packing If the instrument will not use for a long time please switch off ...

Page 14: ...requency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense 11 Specifications Items Specifications Digital model Classic model Voltage VAC 1...

Page 15: ...LED Temperature display accuracy C 1 The safe temperature of hotplate 320 Temperature sensor in medium PT1000 Control accuracy of heating temperature with temperature sensor 0 5 Residual heat warning 50 Dimensions mm 220 160 95 Items Specifications Digital model Classic model 220 160 75 Weight kg 1 4 0 7 0 7 Permitted ambient temperature C 5 40 Permitted relative humidity 80 Protection class acc t...

Page 16: ...9999 MS H280 Pro BlueSpin Double LED Digital Hotplate Magnetic Stirrer stainless steel with corrosion resistant coated hotplate USA plug 100 120V 50Hz 60Hz 861131129999 MS H280 Pro BlueSpin Double LED Digital Hotplate Magnetic Stirrer stainless steel with corrosion resistant coated hotplate Cn plug 200 240V 50Hz 60Hz 861131229999 MS H280 Pro BlueSpin Double LED Digital Hotplate Magnetic Stirrer st...

Page 17: ...gth 230mm 18900136 PT1000 B Temperature sensor with glass coated 230mm 18900148 Support clamp of PT1000 18900080 Reaction block for 50ml round bottom flask one flask capacity 18900081 Reaction block for 100ml round bottom flask one flask capacity 18900082 Reaction block for 250ml round bottom flask one flask capacity 18900083 Reaction block for 500ml round bottom flask one flask capacity 18900006 ...

Reviews: