background image

cause harmful interference in which case the user will be 

required to correct the interference at his own expense. 

 

This instrument is warranted to be free from defects in 

materials and workmanship under normal use and service, 

for a period of 24 months from the date of invoice. The 

warranty is extended only to the original purchaser. It shall 

not apply to any product or parts which have been damaged 

on account of improper installation, improper connections, 

misuse, accident or abnormal conditions of operation. 

For claims under the warranty please contact your local 

supplier. You may also send the instrument directly to 

manufacturer, enclosing the invoice copy and by giving 

reasons for the claim

Summary of Contents for HB120-S

Page 1: ...B120 S LED Digital Dry Bath Please read the User Manual carefully before use and follow all operating and safety instructions Technical specifications and outline are subject to change without prior n...

Page 2: ...anty 1 Safety Instructions 2 Proper Use 3 Inspection 4 Control 5 Trial Run 6 Function Heating 7 Function timing 8 Faults 9 Maintenance and Cleaning 10 Associated Standards and Regulations 11 Specifica...

Page 3: ...em i e hardware or software Methods and procedures adopted to resolve the problems Your contact information Warranty Changes or modifications not expressly approved by the party responsible for compli...

Page 4: ...nths from the date of invoice The warranty is extended only to the original purchaser It shall not apply to any product or parts which have been damaged on account of improper installation improper co...

Page 5: ...es or under water Temperature must always be set at least 50 lower than the fire point of the media used Be aware of hazards due to Flammable materials or media with a low boiling temperature Overfill...

Page 6: ...n residential areas or other constraints mentioned in Chapter 1 3 Inspection 3 1 Receiving Inspection Unpack the equipment carefully and check for any damages which may have arisen during transport Pl...

Page 7: ...ch button Press the button can set the target temperature Time switch button Press the button can set the target time LED Display LED displays the real working state and all settings LED Lignt The LED...

Page 8: ...in time display area will be flashing and then rotate the parameter setting knob to set the target time press the parameter setting knob to turn on the setting The LED time light will turn green then...

Page 9: ...n cannot display the actual temperature of sample in the vessel or dry bath surface temperature differences as following Dry bath center and outer edge The sample in the vessel and dry bath surface 7...

Page 10: ...alcohol Construction materials Water containing tenside Isopropyl alcohol Cosmetics Water containing tenside Isopropyl alcohol Foodstuffs Water containing tenside Fuels Water containing tenside Table...

Page 11: ...t NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection a...

Page 12: ...ensions W D H mm 175 290 85 Weight kg 1 6 without heating block Permissible ambient temperature 5 40 C Permissible relative humidity 80 Protection class according to DIN EN 60529 IP 21 Table 5 12 Orde...

Page 13: ...SCILOGEX LLC 1275 Cromwell Ave Suite C6 Rocky Hill CT 06067 USA Tel 1 860 436 9221 Fax 1 860 436 9745 info scilogex com www scilogex com...