Maintenance

There are no user serviceable part inside

. Your

is thoughtfully engineered for ease of use, accuracy and reliability.

The instrument is carefully tested and calibrated using standards traceable to

National Laboratories.

Take care of your instrument by cleaning the exterior of the instrument regularly

with a dusting brush. Dirt which is difficult to remove on the casing & plastic parts,

can be removed with a moist cloth ( 99% water, 1% mild detergent) spirit or

washing benzene(petroleum ether) can be used to remove greasy dirt. The display

may be cleaned with water or washing benzene (but not with spirit-alcohol

solvents), it must then be wiped with a dry clean lint-free cloth. Under no

circumstances the cleaning fluid should get into the instrument. The use of

cleaning agents can attack the plastic & paint surfaces.

The power line fuse is located on rear panel on lower right side. In case, the

instrument does not show any sign of working, no LED is lit or there is no display

immediately switch OFF the mains power switch of the instrument and unplug the

mains cord from the mains socket. With the help of small flat blade screwdriver

remove the fuse cap of the fuse holder, located just below the socket. There is one

spare fuse kept in the fuse cap, replace it for the defective one. Press the cap so

that it locks in place . The rating of the fuse is 4 A , 250 V , slow blow , 5x20 mm glass

fuse. Do not use a fuse with a higher value

other wise it may damage the

instrument in case, the mains voltage goes much higher than the rating of the

mains fluctuation of 10%.

P D3304

P D3304 Multiple

Power Supply

S

S

Power Line Fuse Replacement

+

Summary of Contents for PSD3304

Page 1: ...User Manual Multiple Power Supply PSD3304...

Page 2: ...nstrument contains proprietary information no part of this manual may be photocopied reproduced or translated without any prior written consent Information in this manual supercede all corresponding p...

Page 3: ...ons 4 5 General Information Safety Operating Conditions First Time Operation 3 Front Panel Controls 4 Operating Instructions 5 Maintenance 8 List of Service Centers 7 10 11 1 13 Power Line Fuse Replac...

Page 4: ...le floated DC output voltages ideally suitable for complex Analog and Digital Testing These floated DC outputs allow operating in series or parallel Outputs are adjustable 0 to 30 V 2A 0 V to 15 V 1 A...

Page 5: ...ad Regulation Line Regulation Temp Coefficient Ripple and Noise Current Limit Output C DC Output Output Current 0 to 30 V 2A 0 to 15 V 1A 4 5 V to 5 5 V 5A 0 30 V cont variable by means of coarse and...

Page 6: ...Weight 3 digit for voltage and current switchable forA B C DC Outputs V 1 1 digit I 1 3 digit By litingA B and C LED Built in overheat over voltage overload protection Between chassis and output 10 M...

Page 7: ...PS 7 Front Panel Control PSD3304 5 7 6 30 0 V 2 00 Multiple Power Supply 3304 PSD Coarse V set I set A 30V 2A B 15V 1A Fine I set Power A B ON OFF 1 2 3 4 10 11 12 13 I set C 5V 5A 8 9 A C 15V 15V V s...

Page 8: ...e output is short circuit protected Variable potentiometer for the current limit setting of the 5 V source Output terminals for DC power supply B 4 mm banana plugs or cable connections The output is s...

Page 9: ...l lit in current mode The instrument is provided with over voltage protection from mains variation The over voltage setting is at 253 V approx Whenever the mains increases beyond the set voltage it tr...

Page 10: ...se of an extension cord without a protective conductor When removing the metal case or replacing the instrument must be completely disconnected from the mains supply If any measurement or calibration...

Page 11: ...on should be noticed Once the instrument is switched ON the power ON is indicated by liting of displays The power supply has an electrically floating output This permits easy series or parallel connec...

Page 12: ...for Series Operation V and V DC Output setting V and V DC Output setting Serial Operation for 65 V 1A Circuit under Test Gnd V V 30 0 V 2 00 Multiple Power Supply 3304 PSD Coarse V set I set A 30V 2A...

Page 13: ...s the cleaning fluid should get into the instrument The use of cleaning agents can attack the plastic paint surfaces The power line fuse is located on rear panel on lower right side In case the instru...

Page 14: ...ls of the fault noticed 2 After receipt of your letter our service department will advise you whether it is necessary to send the instrument back to us for repairs or the adjustment is possible in you...

Page 15: ...damage caused by accident negligence mis application alteration or attempt to repair service or modify in any way 3 This warranty does not include LED fuses batteries or accessories This warranty is o...

Page 16: ...chennai scientificindia com Indira Nagar Adyar Chennai 600 020 Scientific Mes Technik Pvt Ltd Ph 022 24211171 Room No 308 Building No 2 Fax 022 24333654 3rd Floor Sundar Nagar mumbai scientificindia...

Reviews: