background image

Scientific Mes-Technik Pvt. Ltd.,

B-14 Industrial Estate, Pologround,
Indore 452015(India)
Tel : 0731-2422330/31/32/33
Fax : 0731-2422334,561641
Email : [email protected]

Copyright © Scientific All rights reserved.

This instrument contains proprietary information, no part of this manual may
be photocopied, reproduced or translated without any prior written consent.

Information in this manual supercede all corresponding previous released
material.

Scientific continues to improve products and reserves rights to amend part
or all of the specifications, procedures, equipment at any time without
notice.

Rev 1.1 / 0414

2

User Manual PSD3205

Summary of Contents for PSD3205

Page 1: ...User Manual Dual Display Tracking Multiple Power Supply 3205 PSD...

Page 2: ...nstrument contains proprietary information no part of this manual may be photocopied reproduced or translated without any prior written consent Information in this manual supercede all corresponding p...

Page 3: ...tions 5 3 Front Panel ontrols 4 Operating Instructions 8 General Information 8 Safety 8 Operating Conditions 8 First Time Operation 9 Operation 9 6 Maintenance 12 Power Line Fuse Replacement 12 7 Disp...

Page 4: ...as a constant current CC and constant voltage CV source for laboratories industries field testing applications featuring low power loss compact and light weight It provides isolated floated adjustabl...

Page 5: ...0 30 V 3A B 0 30 V 3A 0 30 V continuously variable by means of coarse fine controls 3 A Max Voltage 10 mV Current 5 mA 10 m 2 5 mV at 30 V 3A 50 s 0 05 10 mV 0 05 10 mV 0 05 5mV C 1 mVrms 1 Adjustabl...

Page 6: ...1 Front Panel Controls 6 User Manual PSD3205 30 0 V 3 00 COARSE FINE Imax COARSE FINE Imax POWER ON OFF 3 00 A V TRACK 1 2 3 4 5 6 7 8 9 11 10 A 30V 3A B 30V 3A TRACK DUAL DISPLAY TRACKING POWER SUPPL...

Page 7: ...hat the supplyAis in constant current mode Similarly LED B will lit B is in constant current mode When theTRACK mode is selectedTK LED will lit The instrument is provided with over voltage protection...

Page 8: ...tion must not be negated by the use of an extension cord without a protective conductor When removing the metal case or replacing the instrument must be completely disconnected from the mains supply I...

Page 9: ...ns supply 230 V 10 On switch ON no undue observation should be noticed Once the instrument is switched ON the power ON is indicated by liting of displays The power supply has an electrically floating...

Page 10: ...h shorting clamps connections are done as per above diagram In this mode t he supplyAact as a Master unit B as Slave unit Circuit under Test 30 0 V 3 00 COARSE FINE Imax COARSE FINE Imax POWER ON OFF...

Page 11: ...eeds 240 V AC it is recommended to select 240 V tapping The over voltage setting for safe operation is set at approx 270 V for mains input voltage when the tapping is set to 240 V Whenever the mains i...

Page 12: ...aning fluid should get into the instrument The use of cleaning agents can attack the plastic paint surfaces The power line fuse is located on rear panel on lower right side In case the instrument does...

Page 13: ...l details of the fault noticed 1 After receipt of your communication our service department will advise you whether it is necessary to send the instrument back to us for repairs or the adjustment is p...

Page 14: ...any defect failure or damage caused by accident negligence mis application alteration or attempt to repair service or modify in any way 3 This warranty does not include LED fuses batteries or accesso...

Page 15: ...15 User Manual PSD3205 Notes...

Page 16: ...chennai scientificindia com Indira Nagar Adyar Chennai 600 020 Scientific Mes Technik Pvt Ltd Ph 022 24211171 Room No 308 Building No 2 Fax 022 24333654 3rd Floor Sundar Nagar mumbai scientificindia...

Reviews: