ScienTECH ST4073 Operating Manual Download Page 5

ST4073 

 

 

Scientech Technologies Pvt. Ltd.  

Introduction 

 

Floating DC supply voltages 

 

DC : 0 - 30V; 0-2 Amp 

 

Constant voltage & constant current operation 

 

Digital display for voltage and current 

 

Adjustable current limiter 

The 

ST4073  30V,  2A  Power  Supply

  has  been  designed  as  a 

constant  current  (CC)

 

and 

constant  voltage  (CV)

  source  for  laboratories,  industries  and  field  testing 

applications, featuring low power loss, compact and light weight. It provides floating, 
DC output voltages and is ideally suitable for complex analog and digital applications. 

The  DC  output  can  be  continuously  adjusted  from  0  -30V  with  coarse  and  fine 
controls.  Current  limit  is  also  adjustable  from  0-2A.  Any  over  loading  for  adjusted 
current  limit,  is  indicated  by  flashing  "CC"  LED.  When  the  maximum  setting  is 
crossed or the overheating has occurred, the LED will lit up. 

A  3-digit  display  for  voltage  and  current  is  used  to  read  the  instantaneous  values. 
These  two  parameters  are  switchable  for  indicating  either  voltage  or  current.  In 
addition to low residual ripple and noise, it has excellent line and load regulation. The 
30V- 2A Power Supply is also provided with all  protective circuits to ensure trouble 
free operation. 

Summary of Contents for ST4073

Page 1: ...erating Manual Ver 1 1 An ISO 9001 2000 company 94 101 Electronic Complex Pardesipura Indore 452010 India Tel 91 731 2570301 02 4211100 Fax 91 731 2555643 e mail info scientech bz Website www scientec...

Page 2: ...ST4073 Scientech Technologies Pvt Ltd 2...

Page 3: ...is mandatory that service engineers use lead free solder wire and use the soldering irons upto 25 W that reach a temperature of 450 C at the tip as the melting temperature of the unleaded solder is hi...

Page 4: ...ntry Ground the Instrument This instrument is grounded through the protective earth conductor of the mains cord To avoid electric shock the grounding conductor must be connected to the earth ground Be...

Page 5: ...for complex analog and digital applications The DC output can be continuously adjusted from 0 30V with coarse and fine controls Current limit is also adjustable from 0 2A Any over loading for adjuste...

Page 6: ...cient 0 05 5 mV C Ripple Noise 1mVrms Current Limit Adjustable between 100mA to 2A Display 3 digits for voltage and current Accuracy 1 of reading 1 digit Over Range Indication By flashing CC LED Gener...

Page 7: ...ing knob For the coarse setting of the output voltages 4 I Max adjusting knob For current limit setting adjustment range 2mA 2A 5 Output 0 30 V Output terminals for 4mm banana plugs or cable connectio...

Page 8: ...n cord without a protective Conductor Warning Any interruption of the protective conductor inside or outside the instrument or disconnection of the protective earth terminal is likely to make the inst...

Page 9: ...other Power Supply units to increase supply voltage or current respectively The output power of the 30V 2A Power Supply is not activated by switching on the instrument This is for protection of the lo...

Page 10: ...an be verified on DMM 2 Check of minimum DC output voltage Set the Coarse and Fine knobs to minimum the minimum DC output reading should be 00 0 Volts which when measured on DMM will be approximately...

Page 11: ...The customer resells the instrument to another party d Any attempt is made to service and modify the instrument 3 The non working of the product is to be communicated to us immediately giving full de...