NOTICE:
It is necessary to remove the Shrouds for this procedure. Refer to the “Replace the Shrouds” procedure.
It is necessary to adjust the Drive Belt tension at the end of this procedure. Refer to the “Belt Tension Adjustment” procedure
Note:
Your machine may not match the image. For reference only.
1.
Unplug the AC Adapter from the wall outlet and machine.
2.
Record the position of the Tension Adjustment Nuts (A) on the
Threaded Tensioners (B) on both sides of the machine. Count the threads
or mark a piece of paper.
3.
Carefully remove the Shrouds. Refer to the “Replace the Shrouds”
procedure in this manual.
4.
Using a #2 Phillips Screwdriver, loosen and remove the screws
that attach the lower Fan Cage. Carefully remove the lower Fan Cage
sections. Set them safely aside for reassembly.
5.
Using a 19mm open end wrench, loosen the Fan spindle lock nuts
(C) on the Threaded Tensioner (B) on both sides of the machine.
6.
Using a 10mm open end wrench, loosen the Adjustment Nuts (A) on
both sides of the machine.
7.
Slowly turn the Drive Pulley (D) forward and carefully ease the Drive
Belt (E) off the Drive Pulley to the outside from the bottom of the pulley.
Be sure to keep fingers clear of all pinch hazards as
you turn the Drive Pulley.
A
B
C
D
E
Crank arm not shown