TOUCH dew point ventilation 100-600/610/650/660

Maintenance and safety instructions

If it can be assumed that safe operation is no longer possible, the 
device must be taken out of operation and disconnected from the 
power supply. The installation may only be carried out by a quali-
fied electrician who is familiar with the associated regulations. The 
VDE regulations must be observed. 

Warranty

(1) The warranty period is two years from delivery of the goods to 
commercial customers. (2) You are obliged to examine the goods 
immediately and with due care for quality and quantity deviations 
and to notify the seller in writing of obvious defects within 7 days 
of receipt of the goods; timely dispatch is sufficient to meet the 
deadline. This also applies to hidden defects ascertained later on 
from time of discovery. In the event of a violation of the obligation to 
inspect and give notice of defects, the assertion of warranty claims 
is excluded. (3) In the event of defects, the seller shall, at its option, 
grant warranty by means of rectification or replacement delivery. If 
the rectification of defects fails twice, you can request a reduction 
or withdraw from the contract. In the event of rectification, the seller 
does not have to bear the increased costs incurred by moving the 
goods to a location other than the place of performance, provided 
that the shipment does not correspond to the intended use of the 
goods.

If a defect should occur despite all the factory checks, please send 
the device (franked) to us. If you have any technical questions, 
please dial: +49 (0) 89/904 868 - 0 or fax: +49 (0) 89/904 868 - 10.

Power supply

230V / 50Hz / 2,5W

Fan current

max. 5A, 230V

Connection type

Lift clamps

Touchscreen

5“ Zoll

Resolution

0.1 Grad

Measuring range temperature -26°C to +76°C
Accuracy

± 0,5 % 

Measuring range air humidity 5% to 99%
Accuracy

± 1,8 %

Measuring range Dew point

-54°C to +75°C

Accuracy

± 1,8 % 

Probe length

je 10m standard

Special length

max 50m (each sensor)

Dimensions wall housing

165 x 155 x 70mm

Dimensions sensor housing

65 x 92 x 59 cm

Operating temperature control -20°C to 50°C
Operating temperature sensor -20°C to 50°C
Mounting method

wall mounting

Protection class control

IP51

Protection class sensor

IP51

Technical details

Technical changes and errors excepted. Feb. 2020

Schwille - Elektronik 

 Produktions- u. Vertriebs GmbH | 

Benzstraße 1a | 85551 Kirchheim 

Telefon 089 904 868 0 | Fax 089 904 868 10 | www.taupunkt-lueftung.de | [email protected]

The ventilation controllers type 100 - 610/660 is equipped 

with an RTC (Real Time Clock) and stores all climate data 

hourly on your Micro SD (up to 2 GB) / micro SDHC (up to 

32 GB). All values   (dew point, temperature, relative humi-

dity) are recorded inside and outside, as well as the ven-

tilation intervals. Sensor failures are also saved in the file 

(CSV can be read by Excel).

Data storage

 (only with 100-610/660)

Please note: When restarting and reinserting the SD 

card, a RESET must be carried out beforehand. The 

data   on the micro SD card is not deleted. The reset 

button is located on the far left in the control box next 

to the fuse (black).