TOUCH dew point ventilation 100-600/610/650/660

Setting 2: 

min. indoor temperature 8°C

The lowering of the interior temperature at which the 

ventilation stops can be limited. The selection can be 

made between 5 ° C and 30 ° C in 1 degree steps (fac-

tory setting: 8 ° C). To effectively dehumidify a cellar, 

you need a temperature difference between inside and 

outside.

At  a  temperature  difference  of  5  °  C,  dehumidifica-

tion becomes more effective and gets more common. 

In winter you don‘t have to be afraid that the air in the 

basement could get too cold and could freeze (the mini-

mum indoor temperature is taken into account). A good 

mediocrity is the factory setting of 8 ° C. If you now set 

the interior temperature higher, the events in which ef-

fective dehumidification can take place quickly become 

less common.

Setting 3 & 4: 

(only with 650/660)

Change rel. Humidity 45% & max. in-

door temperature 25°C

The settings for relative air humidity and maximum in-

door temperature mentioned in programs 3 and 4 can be 

changed in these settings. 

Please note: This is the maximum interior temperature at 

which ventilation stops.

This setting is necessary and active in the selection of 

winter garden setting and wine cellar setting. With the 

drying room setting, the max. Indoor temperature not ta-

ken into account.

Device information

In the device information, the type of port of the sensors 

inside and outside is shown in the top two lines (e.g. by 

cable / radio). The third line shows whether the factory 

settings have been changed (if yes, see Figure 2).

External radio sensor

If the receiver is plugged into the external radio sensor, 

the control automatically recognizes the radio sensor 

system.

SD Card 

(only for 610/660)

The fourth line shows whether there is an SD card in the 

controller (not included in the delivery). If a card is inser-

ted, the card data size is also displayed, as well as the 

currently used storage space.

Clock 

(only for 610/660)

The time is already set. It can be changed manually 

(does not automatically switch to summer / winter time). 

To do this, press the respective fields of the date / time 

(appear in red). Confirm with OK or arrow keys.

Night shutdown

By means of the night shut-off, you can set the period of 

time during which the ventilation system should not be in 

operation, e.g. from 11 pm to 5 am. The ventilation stops 

during this time, no dehumidification takes place. If the 

night shut-off is active, the display is darkened.

Fan operating time

The operating hours counter totals the ventilated time of 

the fans in hours/minuts/seconds.

Data-link-connector

The Data-link-connector shows:

 

Restart after fault 

 

Sensor implausible

 

SD card write error

If the control is not fully functional, we ask you to tell us 

about the Data-link-connector at the telephone sup-

port. This suggests any errors (sensor / SD card etc.).