TOUCH dew point ventilation 100-600/610/650/660
Setting 2:
min. indoor temperature 8°C
The lowering of the interior temperature at which the
ventilation stops can be limited. The selection can be
made between 5 ° C and 30 ° C in 1 degree steps (fac-
tory setting: 8 ° C). To effectively dehumidify a cellar,
you need a temperature difference between inside and
outside.
At a temperature difference of 5 ° C, dehumidifica-
tion becomes more effective and gets more common.
In winter you don‘t have to be afraid that the air in the
basement could get too cold and could freeze (the mini-
mum indoor temperature is taken into account). A good
mediocrity is the factory setting of 8 ° C. If you now set
the interior temperature higher, the events in which ef-
fective dehumidification can take place quickly become
less common.
Setting 3 & 4:
(only with 650/660)
Change rel. Humidity 45% & max. in-
door temperature 25°C
The settings for relative air humidity and maximum in-
door temperature mentioned in programs 3 and 4 can be
changed in these settings.
Please note: This is the maximum interior temperature at
which ventilation stops.
This setting is necessary and active in the selection of
winter garden setting and wine cellar setting. With the
drying room setting, the max. Indoor temperature not ta-
ken into account.
Device information
In the device information, the type of port of the sensors
inside and outside is shown in the top two lines (e.g. by
cable / radio). The third line shows whether the factory
settings have been changed (if yes, see Figure 2).
External radio sensor
If the receiver is plugged into the external radio sensor,
the control automatically recognizes the radio sensor
system.
SD Card
(only for 610/660)
The fourth line shows whether there is an SD card in the
controller (not included in the delivery). If a card is inser-
ted, the card data size is also displayed, as well as the
currently used storage space.
Clock
(only for 610/660)
The time is already set. It can be changed manually
(does not automatically switch to summer / winter time).
To do this, press the respective fields of the date / time
(appear in red). Confirm with OK or arrow keys.
Night shutdown
By means of the night shut-off, you can set the period of
time during which the ventilation system should not be in
operation, e.g. from 11 pm to 5 am. The ventilation stops
during this time, no dehumidification takes place. If the
night shut-off is active, the display is darkened.
Fan operating time
The operating hours counter totals the ventilated time of
the fans in hours/minuts/seconds.
Data-link-connector
The Data-link-connector shows:
-
Restart after fault
-
Sensor implausible
-
SD card write error
If the control is not fully functional, we ask you to tell us
about the Data-link-connector at the telephone sup-
port. This suggests any errors (sensor / SD card etc.).