Schwille - Elektronik
TOUCH dew point ventilation 100-600/610/650/660
100-600/650
100-610/660
Reset
Reset
Ports
The port assignments for the ventilati-
on controllers 100-600 / 650 and 100-
610 / 660 including data storage are
shown on the right.
The sensors are connected to the
RJ11 sockets using the supplied
cable. Please pay attention to the as-
signment of the indoor and outdoor
sensors.
The lift clamps are used to connect
the fans. Supply voltage 230V AC. 5A
fuse.
Please note with type 100-610/660:
The RESET must be carried out when
a Micro SD card / SDHC card is in-
serted. The RESET button is located
on the left in the control box.
Operating instructions for Dew Point Touch 600/610 and Universal Touch 650/660
We take nature to our aid and dehumidify with dry air from outside in a very cost-effective way than the known, expen-
sive remedial measures, which are mostly without long-term success. An automatic ventilation system provides a per-
manent solution here. This should be designed as cross ventilation with at least two (in larger basements several) fans
with high air performance. We also have the fitting fans for our ventilation systems in our range.
Voltage Output
2x2,5A/230V
Voltage Output
2x2,5A/230V
5A mt
5A mt
indoor
sensor
indoor
sensor
outdoor
sensor
outdoor
sensor
Power supply
230V
Power supply
230V