Schweigen UM422G-12S Installation Manual Download Page 3

Page 3

1. 

Welcome

Thank you for purchasing your new Schweigen rangehood.

To get the maximum output from this unit, please read through this guide before use.

The guide contains important information on the use and maintenance of the unit, as well as important 
safety notes. This will ensure your personal safety and the lasting value of your rangehood.

We trust that you will enjoy your new Schweigen rangehood.

Please always retain your proof of purchase to aid in any warranty queries.

If you are unable to locate your warranty card, one is available to download from our website  

www.schweigen.com.au.

This appliance and its packaging are produced by processes that minimise waste and respect  
the environment.

Please help us to continue this effort to protect the environment by using the appliance efficiently  
and dispose of the packaging in a responsible manner.

Your State Regulatory Authority

Different Australian states have varying legislative requirements for the installation of rangehood 
ducting. Some will insist on ducting being vented externally (i.e. not in to the ceiling cavity); others  
will not. It is imperative that you check with your state building authority and/or private certifier  
to confirm their position.

Summary of Contents for UM422G-12S

Page 1: ...www schweigen com au RANGEHOOD INSTALLATION GUIDE UM422G 12S Revision V3 01 31 20...

Page 2: ...llation 10 Rangehood Size vs Cooktop Size 10 Mounting Laws and Regulations 10 Recommended Installation Height for Induction Cooktop 11 Ceiling Cassette Installation Guide 12 Optional Bulkhead Installa...

Page 3: ...your warranty card one is available to download from our website www schweigen com au This appliance and its packaging are produced by processes that minimise waste and respect the environment Please...

Page 4: ...person s including children with reduced physical sensory or mental capabilities or lack of experience and or knowledge Unless the person has been given supervision or instruction concerning the use o...

Page 5: ...are made by a qualified technician and that the indicated instructions and local regulations in force are met using materials that are compliant with the applicable legislation 11 The company will no...

Page 6: ...ling cavity When a rangehood is ducted only into the ceiling space the collection of humidity and grease can present very real health issues and fire hazards Recirculating or non ducted or filtered ra...

Page 7: ...lters 9 LED indicator panel 10 Extraction sheets Only to be used as an alternative Please note using the 150mm outlets can reduce airflow NOTE Filter and light quantity may vary from model to model Im...

Page 8: ...ides will illuminate Group 3 Press 3 times 6 lights will illuminate 5 Timer Feature This unit is equipped with a 15min timer function With the fan running press and hold the speed button for 2 seconds...

Page 9: ...y important for the liquid soap to not contain granules that could scratch the surface First apply the solution to a soft cloth and then rub the cloth over the rangehood It is important to follow the...

Page 10: ...r Dishwasher Put the filter in the dishwasher and select a short program at low temperature NOTE The colour of the metal mesh filters may change after several washes This is normal and it is not neces...

Page 11: ...he pins of the light bulb with the larger holes inside the light holder Once the pins are in place turn clockwise to secure the light bulb Step 1 Remove the filters from the rangehood Danger Always sw...

Page 12: ...s cooking zone OPTIMAL Rangehood larger than cooking zone Mounting Instructions The height and position of the rangehood in relation to the cooktop can greatly affect efficiency and extraction After e...

Page 13: ...ant In addition to the information in this manual please check all relevant state requirements for minimum maximum heights as well as regulations regarding the expelling of air Schweigen is not liable...

Page 14: ...ere needs to be a section on the ceiling that corresponds to the sizes given in the technical drawing with support for the rangehood frame Open the split extraction sheet of the device and remove the...

Page 15: ...gehood into a bulk head there needs to be a bulk head made that corresponds to the sizes given in the technical drawing with support for the rangehood Open the split extraction sheet of the device and...

Page 16: ...m 8 Main Power Lead Male Plug 10 Amp 9 Flexi Ducting must be pulled taut DO NOT crush or kink the ducting 10 Connect flexi ducting to the outlet on rangehood using ring clamp Please DO NOT rip the duc...

Page 17: ...8 Flexi Ducting must be pulled taut DO NOT crush or kink the ducting 9 Connect flexi ducting to the outlet on rangehood using ring clamp Please DO NOT rip the ducting 1 2 3 4 5 6 7 8 9 DANGER All elec...

Page 18: ...s The supplied ducting has been manufactured with an allowance for the back draft fins to operate without hindrance It is the smooth extended end of the ducting When installing Back Draft Fins please...

Page 19: ...istance from cooktop to the rangehood Speed of food liquid heating Filter size larger canopy preferred Quality of pots or cookware you are using high quality recommended How to reduce the possibility...

Page 20: ...ht bulbs should be firmly in position Check light bulbs Make sure they are not broken or faulty Please make sure there is no obstruction in ducting or with the back draft fins Check the outlet make su...

Page 21: ...ess to the appliance at their expense Service Lodging an Online Service Request In the event that the failure is not due to the faults mentioned in the Troubleshooting section you can lodge an online...

Page 22: ...Page 22 9 Specifications Technical Specifications Model UM422G 12S Feeding Voltage 220 240V 50Hz Lamp Power Halogen W 6 x 35W Supplied Lamp Power LED W 6 x 3 5W Optional Dimensions 1156 655 700 1200 1...

Page 23: ...be found with the Isodrive Motor or online at schweigen com au Schweigen Home Appliances has presented this information in good faith to all their retailers and distributors to convey before any all p...

Page 24: ...Court Mulgrave 3170 Victoria Phone 1300 881 693 Email sales schweigen com au Web www schweigen com au New Zealand 5 Tolich Place Henderson Auckland 0610 Phone 0800 200 510 Email info parex emerson co...

Reviews: