6.
Installation
DANGER
Always switch off and disconnect the power supply before installing the rangehood.
Failure to do so may cause serious injury.
WARNING
Please remove filters before installation. Failure to do so may damage the clips.
Optional Bulkhead Installation Guide
• To install the rangehood into a bulk head, there needs to be a bulk head made that corresponds
to the sizes given in the technical drawing with support for the rangehood.
• Open the split-extraction sheet of the device and remove the filter before installing.
• Install threaded rods onto the beam and drill holes at the four corners on the rangehood,
adjust the nuts to level the unit.
• Connect the external motor system with the rangehood.
Mounting Holes
Inside View
Bulk Head
Cassette Rangehood
Threaded Rod (Optional method)