2.  Your Safety

 

Receiving your rangehood  ______________________________________________________________________ 4 
Before Installation  ______________________________________________________________________________ 4 
Electrical Cord  __________________________________________________________________________________ 4 
Motor Features  ________________________________________________________________________________ 5 
General Notes on Installation and Use  ____________________________________________________________ 5 
Recommended Installation Distance  _____________________________________________________________ 5 
Minimum Mounting Height  ______________________________________________________________________ 6 
Avoidance of Back Flow  _________________________________________________________________________ 6 
Safety of Children  ______________________________________________________________________________ 6 
Replacement of Supply Cord  _____________________________________________________________________ 6 
Why Schweigen SteelFlex

 Safety Duct  __________________________________________________________ 6

3.  Description

 

Isodrive Motor  _________________________________________________________________________________ 7

4.  Installation

 

Roof Installation  _______________________________________________________________________________ 9 
Wall Installation  ________________________________________________________________________________ 10 
Flat Roof Installation  ___________________________________________________________________________ 12 
Through Wall Installation for Isodrive 900  _______________________________________________ 13 
Fan Unit Shutter Assembly for Isodrive 900 (Optional)  _____________________________________ 14 
Twin 200mm Outlet Installation Example  _______________________________________________ 15

5.  Measurements

 

Measurements for Isodrive 900  ______________________________________________________ 16

6.  SteelFlex

 Safety Duct 

SteelFlex

 Safety Ducting Installation  _________________________________________________ 17 

Assembling SteelFlex

 Safety Duct  ____________________________________________________ 18  

Shallow Roof Space  _______________________________________________________________ 19 
Important Note  __________________________________________________________________ 19 
Installing SteelFlex

 Safety Duct  _____________________________________________________ 20

7.  Parts List 

Parts List for Isodrive 900  ___________________________________________________________ 21

8.  Maintenance

 

Roof Restoration or Cleaning  ________________________________________________________ 23

9.  Warranty/Disclaimer

  ________________________________________________________________________ 24

Summary of Contents for Isodrive 900

Page 1: ...INSTALLATION GUIDE Isodrive 900 www schweigen com au Revision V2 25 11 21...

Page 2: ...unit as well as important safety notes This will ensure your personal safety and the lasting value of your Isodrive system Please always retain your proof of purchase to aid in any warranty queries Th...

Page 3: ..._________________________ 7 4 Installation Roof Installation ________________________________________________________________________________ 9 Wall Installation ______________________________________...

Page 4: ...s indicated on the rating label Before Installation We recommend this appliance to be installed or repaired by a qualified Schweigen Home Appliances technician Please see our website www schweigen com...

Page 5: ...etc General Notes on Installation and Use This fan unit is designed to be installed using 150mm ISD PVC pipe as the initial connection duct to the fan module and is supplied with a 150mm ISD PVC pipe...

Page 6: ...x is antimicrobial treated thermally insulated and acoustically dampened It is fireproof pest and crush proof with a treated surface that prevents the build up of grease and bacteria Schweigen s uniqu...

Page 7: ...Approx 4 metres 200mm 210mm OD1 diameter 4 Bell mouth adapter ring 200mm duct to 150mm riser 5 2 x Steel ring clamps 6 6 x 20mm self drilling button head screws Not included in the box Roof seal kit D...

Page 8: ...coming from the canopy rangehood Refer to figure 4 Do not insert plug into socket outlet or switch on until installation has been completed Fit fan module to pipe and fix in position using side locki...

Page 9: ...o prevent rain water entering the unit Pipe protrusion above dektite Fix fan module using side locking screw Connect to rangehood Connect to power supply NOTE Prevent any cord bunching by pulling cord...

Page 10: ...eard through the system and inhibit the system to run silently Figure 2 Wall Installation Wall Wall Optional Fitment Pipe Optional Mounting Flange P40113MF 150mm PVC Stormwater Pipe From outside face...

Page 11: ...Locking holes at 10 and 4 o clock Cord slots at bottom 6 o clock position NOTE Ensure that power cord is fed through exit slot and is not allowed to double back restricting fan inlet NOTE Prevent any...

Page 12: ...remain 200mm SteelFlex Ducting Seal top edge of flange 50 Protrusion of pipe above mounting flange Bond flange to pipe using silicone urethane or type N PVC solvent cement Optional mounting flange P4...

Page 13: ...r plate with notch at bottom P1108 Minimum pipe protrusion from wall surface Wall cover plate optional part Slot in pipe at bottom 6 O Clock Power cord Ensure that power cable passes through the cover...

Page 14: ...les Alignment can be checked visually by folding in shutter flaps 2 Fully tighten both screws and re check fitment into holes 3 Fit assembly to duct pipe as per installation instructions supplied Atta...

Page 15: ...Try to keep length of SteelFlex ducting as even as possible other wise motors will draw air off each other Ensure SteelFlex ducting is fully extended and as short as possible Use smooth flowing curve...

Page 16: ...Page 16 5 Measurements Measurements for Isodrive 900 Not to Scale 157mm 53mm 278mm 198mm 440mm 160mm 242mm 131mm Dektite Shutter assembly optional is not shown in the diagram...

Page 17: ...flows Incorrect installation may reduce airflow or increase noise levels Call outs relating to incorrect installation will result in a service fee directed to the customer Schweigen will take no respo...

Page 18: ...l mouth adapter ring 200mm duct to 150mm riser 4 150mm PVC riser pipe 5 20mm self drilling button head screws 1 2 3 4 5 NOTE Do not use duct tape to fasten the duct the screws and hose clamp are adequ...

Page 19: ...rely 90 degree curve made of PVC or galvanise can be used as a substitute for the bend refer to figure 12 Figure 12 Figure 13 Important Note Please do not crush or kink SteelFlex ducting as it will re...

Page 20: ...Ducting installed looped over hanging beams should be installed in such a manner as to ensure the changes of direction are gradual Support of the ducting with the use of hangers may be required see op...

Page 21: ...Page 21 7 Parts List Parts List for Isodrive 900 1 2 3 4 5 6 7 8 9 10 11 12...

Page 22: ...0 Terminal Block Cover 1 2 P40121 Wire Insulator Cap 1 3 P1061 O Ring 4 ID 1 4 P1059 Capacitor 2 F 1 5 P807 Terminal Block 1 6 P40102 Fan Plate Motor Mount 1 8 P40122 900 Inlet Shroud Mount 1 9 P1069...

Page 23: ...doing your roof restoration or cleaning please completely cover the outside motor system and avoid all chemical contact IMPORTANT Any damages caused by the use of chemical products are not covered by...

Page 24: ...er Under our policy of continuous product development product specifications may change without notice Prospective purchasers should therefore check with the retailer to ensure this publication correc...