Page 6
Minimum Mounting Height
This fan unit is intended for mounting at a minimum height of 2.1 metres (measured to the lower part of the
fan impeller) above a floor or the ground.
Avoidance of Back Flow
Care should be taken to avoid the back flow of gases into the room from the open flue of gas or other open fire
appliances.
Safety of Children
This fan is not intended for use by young children or infirm persons without supervision.
Replacement of Supply Cord
If the supply cord is damaged, it must be replaced by a service agent or suitably qualified person in order to
avoid a hazard.
Why Schweigen SteelFlex
™
Safety Duct
Schweigen SteelFlex
™
is an ultra-strong and flexible high-performance safety ducting made
of Shirikon Firemesh
®
– a tri-layer tear-resistant UV-treated sleeve. Both are developed by
Schweigen – the Silent Rangehood specialists, for quiet and efficient high-volume transfers
of temperature-sensitive air. Engineered to enhance the health and safety of your home,
Schweigen SteelFlex
™
is antimicrobial treated, thermally insulated and acoustically dampened.
It is fireproof, pest and crush proof with a treated surface that prevents the build-up of grease
and bacteria.
Schweigen’s unique Isodrive system works in the opposite way to conventional rangehoods, pulling air through
the hood and acoustically matched ducting, producing almost silent high volume flow. The use of a complete
rigid or semi-rigid ducting system will allow an organ piping effect to occur; like a didgeridoo where a noise is
produced at one end of a hollow rigid pipe and the noise is amplified out the other.
The Isodrive system places the noise outside the house.
WARNING:
Installation without the use of at least the minimum recommended length of acoustically matched
SteelFlex
™
in the system will void performance expectations. Any installation problem must be reported
to Schweigen. Call outs relating to incorrect installation will result in a service fee direct to the customer.
Schweigen takes no responsibility for problems caused by faulty installation, this may void warranty. A
preferred installer list can be obtained from Schweigen website
www.schweigen.com.au
or by calling
1300 881 693
.
2. Your Safety