- 9 -
4.3. How to read and modify time and date
To read and modify time and date, the
button has to be pushed.
All control circuits include a separate time-program. This function takes place at the collective
clock. At first the time is shown (in the picture: 14:03). Afterwards you have to use the
button
again, to be able to change the year (2007), after pushing the
button for the third time month
and day (in this case: 3 = March 21) are announced. „3 Day” stands for the third day in the
ongoing week, in other words: Wednesday. ( 1= Monday, etc.)
After using the
button once more the display switches back to the normal clock.
The display ends at the base display, if you press the
DISP
button.
Setting the time
To change the time, the
SEL
button has to be
pressed. At first the
minutes start to blink
(03), which can be
modified by using
+/-
.
After pushing the
SEL
button again, the hours
will start to blink. (14)
The hours can also be
changed with the
+/-
buttons.
The setting of the time
can be finished by using
the
button.
Afterwards the display
goes back to the year.
Remark: symbols or figures, which are framed are
blinking ones!
Summary of Contents for ThermoControl Plus M2
Page 27: ... 27 Wiring diagram ThermoControl Plus M 1 2 4 1 4 zones two stage luminous heater ...
Page 28: ... 28 Wiring diagram ThermoControl Plus M 1 2 4 1 4 zones modulating luminous heater ...
Page 29: ... 29 Wiring diagram ThermoControl Plus M 1 2 4 1 8 zones single stage tube heater ...
Page 30: ... 30 Wiring diagram ThermoControl Plus M 1 2 4 1 4 zones two stage tube heater ...
Page 31: ... 31 Wiring diagram ThermoControl Plus M 1 2 4 1 4 zones modulating tube heater ...
Page 32: ... 32 Wiring diagram ThermoControl Plus M 1 2 4 1 4 zones warm air heater aeroSchwank AR and AT ...
Page 33: ... 33 Wiring diagram warm air heater AR and AT ...