background image

1

 

 

 

 

Use Instruction 

 

 

 
 
 
 
 
 

 

Schwank GmbH - Bremerhavener Str. 43 - D 50735 Cologne 
Tel: +49 (0)221-7176-0 

 

Fax: +49 (0)221-7176-288 

www.monsterfans.com   

[email protected] 

 
 

 

 
Language:  Englisch  
Date:   

10. September 2020   

Revision: 

V 1.1 

Summary of Contents for 195 80 200

Page 1: ...se Instruction Schwank GmbH Bremerhavener Str 43 D 50735 Cologne Tel 49 0 221 7176 0 Fax 49 0 221 7176 288 www monsterfans com info monsterfans com Language Englisch Date 10 September 2020 Revision V...

Page 2: ...stems 8 4 3 Required Installation Environment 9 4 4 Mounting Sets 10 4 5 Extension Elements 11 4 6 Installation of MonsterFans 11 4 7 Oil Check and Oil Safety Pin 14 5 Frequency Converter 15 6 Commiss...

Page 3: ...132 kg Motor Power 1 5 kW 2 hp Max Electrical Consumption 3 23 A 3 23 A 3 23 A 3 23 A Supply Voltage 3 400 V 50 Hz Max Coverage Range 630 m2 850 m2 1 380 m2 1 800 m2 Sound Pressure Level 55 dB measure...

Page 4: ...lisation during operation The fan shall not be operated in windy surroundings We recommend also securing the floor under the assembly so that attention is drawn to the work on the ceiling Review all r...

Page 5: ...the ceiling in accordance with the specified safety distances The fan s wings are installed at least 3 5 m above the floor The fan is installed with a minimum distance of 2 times the fan diameter fro...

Page 6: ...Overview MonsterFans 1 Steel structure 2 Safety rope ring 3 Steel structure fastening 4 Extension tube 5 Motor housing 6 Winglets of fan blades 7 Fan blades 8 Turnbuckle clamps 9 Safety steel rope 10...

Page 7: ...5 x 12 mm 8 Bottom plate 1x replacement blade retainer 5x 5x 9 Safety steel rope 10 Steel wire lock 11 Fastener 12 Fastener 60m length 28x M12 x 80 mm M16 x 55 mm 10x 4x 13 Fastener 14 Metal joint on...

Page 8: ...ielded 4 x 2 5 mm Cable Shears Wire Stripper Multimeter Distance Meter Threadlocker Glue Please also note the necessary safety precautions for the use of a scissor lift and the general safety precauti...

Page 9: ...on Location Inside Temperature Range 15 55 C Please do not use the product in environments with strong temperature fluctuations The product must not be exposed to frost Humiditiy Below 95 relative hum...

Page 10: ...ing set for concrete structure Optional mounting set for side mount on concrete Optional mounting set for bent structure Standard Mounting Set for I Beam Article no 19580220 Weight 14 kg Mounting Set...

Page 11: ...n set may be used to connect two extension elements Otherwise the stability of the fan can be influenced Extension tube Optional Extension tube 1 m length 1 5 m standard length Article no 19580230 Art...

Page 12: ...l wire lock no 10 Mount the motor housing with the motor on the extension element Use the M16 x 120 mm screws for this Pay attention to an exactly horizontal alignment Note The safety steel ropes must...

Page 13: ...o connect all retaining brackets parts list no 6 to each other Then install the bottom plate parts list no 8 with the screws M5 x 12 mm no 7 Now lay the wiring to the control unit Controller box Use y...

Page 14: ...s AC 4 7 Oil Check and Oil Safety Pin Please also check the oil level before starting up There is a safety pin on the bleed screw The safety pin must be removed before the initial start up The engine...

Page 15: ...ated in the MonsterFans Controller Box You will find detailed technical instructions from the manufacturer attached The frequency converter is pre programmed at the factory and is ready for operation...

Page 16: ...a residual voltage Please check this before working or wait 2 minutes till electricity will drop completely A switched off display is not an indication that the voltage has reached the safety level in...

Page 17: ...he Run Stopp button Unauthorised personnel must not open the Controller Box Our local service partner will send you a trained specialist for repairs or adjustments If you notice that the fan or Contro...

Page 18: ...and cabling 5 Check the gearbox for oil leakage 6 Check all suspension and connection elements 7 Check the wing connection bolts under the base plate 8 Check the wings and engine components for damag...

Page 19: ...m 520 mm Wooden box fan blades 3700 mm 420 mm 450 mm 180 kg 127 kg 307 kg MF C20 on request 6 1 m 20 ft Wooden box Motor 950 mm 830 mm 520 mm Wooden box fan blades 3100 mm 420 mm 450 mm 180 kg 117 kg...

Page 20: ...t any problems No vibrations no noise no error messages Yes No Blades are undamaged Yes No The instruction by technician to customer has taken place Yes No 10 min test run was problem free Yes No Inst...

Page 21: ...ings and engine components for damage 9 Check all fan components for signs of corrosion discoloration pitting and metal spalling 10 Check the guy wires for damage or abrasion 11 Removal of dust and di...

Page 22: ...www monsterfans com info monsterfans com 22 12 Declaration of Conformity...

Page 23: ...www monsterfans com info monsterfans com 23 Schwank GmbH Bremerhavener Stra e 43 D 50735 Cologne Tel 49 0 221 7176 0 Fax 49 0 221 7176 288 www monsterfans com info monsterfans com...

Reviews: