17
LNB cable installation
(See installation diagram on the following page)
For the installation of the F connectors on the coaxial
cable you will need a knife (ideally a wire stripper) and
side cutting pliers.
When stripping the isolation, neither the inner
core or the foil nor the wire netting must be
damaged.
Cut 8 mm of the coaxial cable at each end up to the
inner core.
Carefully cut 10 mm of the outer insulation so that the
wire netting is exposed.
Turn the wire netting backwards and wind it over the
outer insulation in such a manner that it does not touch
the inner core.
Remove the inner insulation together with the foil
placed over it up to 2mm before reaching the wire
netting.
Caution
The wire netting and the foil must not touch the inner
core. The foil must enclose the inner insulation and
must not be damaged.
Rotate the F connector onto the turned-back wire
netting until the connector touches the inner insulation.
The wire netting must not protrude from the back
of the connector.