Function
slides of the quick-change pallet module moves into the closed
position. Exchanging the clamping pallet is not possible with
clamping modules that are not locked.
WARNING
Risk of injury due to clamping pallet falling from the clamping
station if the unlocking connection is not scheduled pressurized
according to schedule.
•
The unlocking connection may only be operated if the
clamping pallet has been prevented from falling.
5.3 TURBO connection (with NSL 3-V1)
NSL3 -V1 clamping stations are equipped with an additional turbo
connection. When compressed air is applied at the connection for
the turbo function, this function actively provides air pressure to
support the spring-actuated locking procedure of the quick-change
pallet module. This increases the pull-in force in all the modules.
One pressure pulse is sufficient to increase the pull-in force until
the maximum permissible value is reached. Afterwards, the
clamping station can be switched back to depressurized. The pull-
in force is retained due to the self-locking function of the spring-
loaded system.
Air connection G1/8"
turbo function (with NSL3 -V1)
Locking coupling type
NW 7.4 (accessory)
Sealing nipple NW 7.4
(scope of delivery)
Open air connection
G1/8" module
Connections on the clamping station
35
03.00 | NSL3 | VERO-S quick-change pallet system | en | 1155408