Troubleshooting
01.00|KSH3, KSH3-LH, KSH3-F |en
27
Troubleshooting
Clamping force block chuck jaws will not move
Possible cause
Solution(s)
Oil supply interrupted
Check the hydraulic supply
System pressure too low
Increase system pressure according to clamping
system technical specifications
Connections mixed up
Check connections and functions and connect
properly
Hydraulic connections that are in use
are closed
Check connections and open
Clamping force block does not complete stroke
Possible cause
Solution(s)
Chips or dirt between covering strip
and base jaws
Unscrew the covering strip (item 8) and remove
chips and dirt
Clamping force getting weaker
Possible cause
Solution(s)
Clamping force block not sealed tightly Check connection and seal screws; reseal or
replace
Seals damaged
Disassemble clamping force block
and replace all the seals (see
Inadequate lubrication
Lubricate the lubrication nipples with LINOMAX
Clamping force block movement jerky
Possible cause
Solution(s)
Steel guide rollers on sliding surfaces
not greased
See chapter "Maintenance and Care"
Monitoring functions of the jaw stroke positions do not work
properly
Possible cause
Solution(s)
Monitoring pieces in the base jaws not
positioned exactly
Readjust monitoring piece for the required
Pressure change due to clamping
stroke too low
Adjust clamping stroke to the workpiece to >0.3
mm/jaw
Seals damaged
Replace seals in cover and adapter plate