Assembly
22
05.00 | SFL | Assembly and operating manual | en | 389398
5.2.3 Design suggestion for adapter plate
Adapter plate for lateral mounting of the SFL
Item Mounting
25
40
64
7
Bore holes for the centering
sleeves [mm]
5
8
10
Depth of the bore holes [mm]
2
2.5
3
8 *
Min. recess depth [mm]
1
1
1
9 *
Groove length for adjusting the
magnetic switch [mm]
18
30
40
*
When designing the adapter plates for the lateral mounting of
the swivel unit, ensure that, in case of the sizes 25 and 40, the
sensors can slightly protrude MMS 22 over the housing after the
assembly. The adapter plates can be implemented as illustrated in
the example. Observe the above points (8) and (9).
NOTICE
Ferromagnetic adapter plates have a strong influence on the
process reliability of the magnetic switch monitoring.
•
For process-reliable monitoring, the adapter plates and the
attachments in the closer surrounding of the swivel unit
should be made of non-ferromagnetic material.